2.5 CEILING MOUNTED INSTALLATION
WARNING
Heater should be hung using rigid mounting brackets, the unit must not
be able to swing in any direction under applied load from wind or
persons. It is highly recommended that users install the heater with the
ceiling mounting hardware provided.
HEATER POSITION MUST MAINTAIN A MINIMUM CEILING CLEARANCE OF
0.2m (8”)
1. Select the installation location on the ceiling by
identifying the studs or structural beams that
will allow the heater to be securely attached.
NOTE: ceiling bolts or anchors are not supplied.
Select an appropriate size to provide adequate
support for the weight of the unit and take into
consideration any wind load conditions.
2. Attach the unit to the ceiling using the mounting
brackets provided and user selected bolts.
3. The heater can be hung vertically or pointed at
a maximum angle of 70° from vertical. DO NOT
point the heater at the wall or ceiling!
NOTICE: NEVER direct the infrared heat produced
by the appliance at an adjacent wall.
4. Secure the electrical supply cable so it does not
contact with the heater body or cover the
heater air vents.