WARNING! Federal law (49 cfr part 571) requires that the Final Stage Manufacturer of
a vehicle certify that the vehicle complies with all applicable federal regulations. Any
modifications performed on the vehicle prior to the final stage are also considered
intermediate stage manufacturing and must be certified as to compliance. The installer of
this crane and body is considered one of the manufacturers of the vehicle. As such a
manufacturer, the installer is responsible for compliance with all applicable federal and
state regulations, and is required to certify that the vehicle is in compliance.
WARNING! It is the further responsibility of the installer to comply with the OSHA
Truck Crane Stability Requirements as specified by 29 CFR part 1910.180 (C) (1).
WARNING! NEVER OPERATE THE CRANE NEAR ELECTRICAL
POWER LINES!
Death or serious injury will result from boom, line, or load contacting
electric lines. Do not use crane within 10 feet (3.05m) of electric power lines carrying up to
50,000 volts. One foot additional clearance is required for every additional 30,000 volts or less.
WARNING! NEVER .............................
v EXCEED load chart capacities (centerline of rotation to hoist hook).
v un-reel last 5 wraps of cable from drum!
v wrap cable around load!
v attempt to lift or drag a load from the side! The boom can fail far below its rated capacity.
v weld, modify, or use unauthorized components on any Auto Crane unit! This will void any
warranty or liability. Also failure of the crane may result.
v place a chain link on the tip of the hook and try to lift a load!
v use a sling bar or anything larger than the hook throat that could prevent the hook latch from
closing, thus negating the safety feature!
v hold on any pendant Select Switch that will cause unsafe operating conditions!
WARNING! In using a hook with latch, ALWAYS make sure that the hook throat is closed
before lifting a load! Proper attention and common sense applied to the use of the hoist hook and
various slings will prevent possible damage to material being hoisted and may prevent injury to
personnel.
WARNING! Failure to correctly plumb and wire crane can cause inadvertent operation and
damage to crane and/or personnel!
WARNING! Auto Crane Company remote controlled cranes are not designed or intended to
be used for any applications involving the lifting or moving of personnel.
WARNING! ALWAYS operate the crane in compliance with the load capacity chart.
Do not use the overload shutdown device to determine maximum rated loads, if your crane is
equipped with this type of device.