RST2
RESET
BATCH PV
BATCH SV=2
OUT1
0
Mode D (
d
)
When the count present value PV counts up or counts down to the count setting value SV, Output 2 will turn ON
momentarily for the time set in the output pulse width parameter (
tout2
) and the batch count present value BATCH
PV will increment by one. The count PV will continue to increment or decrement with each input signal.
The leading edge of a “reset” input signal at RST1 will turn OFF Output 2, reset the count PV to 0, and prohibit an
input signal from incrementing the count PV. The trailing edge of the “reset” signal at RST1 enables counting to begin.
When the BATCH PV counts up to the BATCH SV, Output 1 will turn ON. The leading edge of a “reset” input
signal at RST2 will turn OFF Output 1, reset the BATCH PV to 0, and prohibit an input signal from incrementing
the BATCH PV. The trailing edge of the “reset” signal at RST2 enables counting to begin.
The “reset” signal minimum pulse width is set by reset pulse width parameter ( rtSr ) or DIP Switch 8.
BATCH
Input Mode UdC