5-98
Chapter 5: Standard RLL Instructions
1
2
3
4
5
6
7
8
9
10
11
12
13
14
A
B
C
D
NOTE: Status flags are valid only until another instruction uses the same flag.
In the following increment example, when C5 makes an Off-to-On transition the value in
V1400 increases by one.
In the following decrement example, when C5 makes an Off-to-On transition the value in
V1400 is decreased by one.
A aaa
INC
A aaa
DEC
DirectSOFT
C5
INC
V1400
Increment the value in
V1400 by “1”.
V1400
8935
V1400
8936
Handheld Programmer Keystrokes
STR
$
5
F
ENT
8
I
ENT
NEXT NEXT NEXT NEXT
SHFT
TMR
N
1
B
4
E
0
A
0
A
2
C
Operand Data Type DL06 Range
A
aaa
V-memory V See memory map
Pointer P See memory map
Discrete Bit Flags Description
SP63 On when the result of the instruction causes the value in the accumulator to be zero.
SP75 On when a BCD instruction is executed and a NON–BCD number was encountered.
DirectSOFT
C5
DEC
V1400
Decrement the value in
V1400 by “1”.
V1400
8935
V1400
8934
Handheld Programmer Keystrokes
STR
$
5
F
ENT
3
D
ENT
NEXT NEXT NEXT NEXT
SHFT
4
E
1
B
4
E
0
A
0
A
2
C
DS Used
HPP Used
DS Used
HPP Used
Increment (INC)
The Increment instruction increments a BCD value in a
specified V-memory location by “1” each time the instruction
is executed.
Decrement (DEC)
The Decrement instruction decrements a BCD value in a
specified V-memory location by “1” each time the instruction