DL06 Micro PLC User Manual, 3rd Edition, Rev. E
5-289
Chapter 5: Standard RLL Instructions
1
2
3
4
5
6
7
8
9
10
11
12
13
14
A
B
C
D
ECEMSUP Parameters (cont’d)
• Port Number: optional parameter that specifies the TCP/IP Port Number to send SMTP requests;
usually this does not to be configured (see your network administrator for information on this setting)
• Timeout (sec): optional parameter that specifies the number of seconds to wait for the SMTP Server
to send the EMail to all the recipients
• Cc: optional parameter that specifies a list of “carbon copy” Email addresses to send all EMails to
Parameter DL06 Range
ECOM100# K K0-255
Workspace V See DL06 V-memory map - Data Words
Success X,Y,C,GX,GY,B See DL06 V-memory map
Error X,Y,C,GX,GY,B See DL06 V-memory map
Error Code V See DL06 V-memory map - Data Words