B-40
BF4 Series
Mutual Interference Prevention
Function (common)
Two fiber optic cables can be mounted very closely by
setting different transmission frequencies.
●Interference prevention function
(operation of differential frequency mode)
Self-Diagnosis Function (common)
When fiber hood is contaminated by dust, transmitted
light is lowered by element ability loss or received light is
lowered by missing of optical axis, the self-diagnosis output
will turn on.
● When detecting state remains over 300ms at unstable light
ON/OFF level, the self diagnosis output turns ON. In case
of stable light ON/OFF level, the self diagnosis output turns
OFF. (
position)
In case of Light ON
Stability
indicator
(green LED)
Self-diagnosis
output
Control output
indicator
(red LED)
Stable light
ON level
Unstable light
ON level
Unstable light
OFF level
Operation
level
Stable light
OFF level
Light
received
300ms
300ms
ON
OFF
ON
OFF
ON
OFF
H
L
First sensor- Frequency 1 (response time: max. 0.5ms)
Second sensor- Frequency 2 (response time: max. 0.7ms)
Set the mode setting switch to [
LOCK
].
Set the mode setting switch to [
SET
].
Press the [
ON
] + [
OFF
] buttons for
2 sec at the same time.
The Stability indicator [
STAB
] flashes
continuously.
Press the [ON] button.
The Stability indicator [
STAB
] turns off.
Set the mode setting switch to [
LOCK
].
Set the mode setting switch to [
SET
].
Press the [
ON
] + [
OFF
] buttons for
2 sec at the same time.
The Stability indicator [
STAB
] flashes
continuously.
Press the [OFF] button.
The Stability indicator [
STAB
] turns off.
Flashing
Flashing