B-22
BF5 Series
Group teaching
A function to set the sensitivity of Slave amplifier units according to the command of Master amplifier unit(a certain
amplifier unit) in a successive and collective way.
When group teaching is executed,
the Master unit transmits teaching
command to each Slave unit and
channel No. and "
OK
" is displayed.
Ex) In case of 8 channels
Select "
NO
" and press
key
to return to RUN mode.
The Master unit starts teaching after
teaching command transmission to
Slave unit is completed.
Automatically
executed
Automatically
executed
Automatically
executed
Automatically
executed
Automatically
executed
Automatically
executed
Automatically
executed
Automatically returned to RUN mode
when group teaching is completed.
Automatically returned to
RUN mode .
Teaching for each Slave unit is
executed in sequence.
Group teaching is executed
after teaching command is
transmitted form the Master
unit.
Master unit
RUN mode
Flashes in turn
(every 0.5 sec.)
Flashes twice
(every 0.5 sec.)
Flashes twice
(every 0.5 sec.)
Flashes twice
(every 0.5 sec.)
Teaching SV flashes
twice(every 0.5 sec.)
Flashes in turn(every 0.5 sec.) Flashes in turn(every 0.5 sec.)
Slave unit
RUN mode
Press key 3sec.
Select "
YES
" and prss
key
to execute group teaching.
TCHI ALL
TCHI ALL
TCHI NO TCHI YES
CH2 OK
CH3 OK
CH4 OK
CH8 OK
TCHI END
Teaching
processed
※
1
Teaching
processed
※
1
END
END
2000
2000
2000
key
RUN mode
※
Overbar "----" is indicated in
sequence during group teaching.
0 sec. 0.5 sec. 1 sec. 1.5 sec.
※
1: Display part status while teaching is in the process
Light ON / Dark ON switching function
A function to set Light ON - control output is ON when incident light level is higher than setting value and Dark ON - control
output is ON when incident light level is lower than setting value.
BF5R-S1- (Single display type) model uses the front slide switch to set each mode.