EasyManua.ls Logo

Autonics BF5R-D1-P - User Manual

Autonics BF5R-D1-P
15 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
B-9
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
power
supply
(Q)
Stepping
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
Specifications
The temperature or humidity mentioned in Environment indicates a non freezing or condensation environment.
BF5 Series Fiber Optic Amplier
Please read “Caution for your safety” in operation
manual before using.
Dual digital display type fiber optic amplifiers
Features
● Dual-display for light incident level and setting value(BF5 -D)
● Minute object sensing available with 1/10,000 high resolution
● Enables to detect with high-speed(20,000 times per sec.) moving objects
● 4 response speeds
: Ultra fast mode(50
), high speed mode(150
),
standard mode(500
), long distance mode(4ms)
● Long lasting amplifier regardless of element’s life degradation
or temperature change
● Multiple sensitivity setting modes available
: auto tuning, 1 point(maximum sensitivity), 2 point, positioning teaching
● Up to 8 units enable to stack with mutual interference prevention function
using side connectors
Auto channel setting function for multiple installations
● Slim design(W10×H30×L70mm)
Model
Display type Dual Display type Single Display type
NPN open collector output
BF5R-D1-N BF5G-D1-N BF5B-D1-N BF5R-S1-N
PNP open collector output
BF5R-D1-P BF5G-D1-P BF5B-D1-P BF5R-S1-P
Light source
Red LED
(660nm, modulated)
Green LED
(530nm, modulated)
Blue LED
(470nm, modulated)
Red LED
(660nm, modulated)
Power supply 12-24VDC±10%
Current consumption Max. 50mA
Operation mode Light ON / Dark ON Selectable
Control output
NPN or PNP open collector
●Load voltage: Max. 24VDC ●Load current: Max. 100mA ●Residual voltage
-
NPN:Max. 1V, PNP:Max. 3V
Protection circuit Reverse polarity protection, overcurrent protection, surge absorption
Response time Ultra Fast : 50
, Fast : 150
,STD : 500
, Long : 4ms Fast : 150
, STD : 500
, Long : 4ms
Display method
●Incident light level: Red, 4digit, 7Segment
●SV : Green, 4digit, 7Segment
●Main output indicator : Red LED
●Incident light level / SV : Red, 4digit, 7Segment
●Main output indicator : Red LED
Display function
Incident light level / SV display [4,000/10,000 resolution], Percentage display, High/Low peak value display,
Normal / Reversed display
Sensitivity setting
Auto tuning, 1 point teaching,
2 point teaching, Positioning teaching
Auto tuning
Mutual interference
prevention
Max. 8 unit sets (Automatically set regardless of response time)
Initializing Initializing to factory mode
-
Energy saving Normal / Energy saving 1 / Energy saving 2
-
Timer OFF, OFF Delay, ON Delay, One-shot OFF, 10ms OFF Delay timer, 40ms OFF Delay timer
Insulation resistance Min. 20MΩ(at 500VDC megger)
Dielectric strength 1,000VAC 50/60Hz for 1 min.
Vibration 1.5mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each X, Y, Z directions for 2 hours
Shock 500m/s
2
(Approx. 50G) in each X, Y, Z directions for 3 times
Environ-
ment
Ambient illumination
Incandescent lamp : Max. 3000
Sunlight : Max. 11000
Ambient temperature
-10 to 50
, storage: -20 to 70
Ambient humidity
35 to 85%RH, storage: 35 to 85%RH
Protection IP40(IEC standards)
Material Case : PBT, Cover : PC
Fiber cable
Tightening torque
Min. 2kgf
Accessory
Connector type wire(ø4, 3-wire, 2m) (AWG22, Core diameter: 0.08mm, Number of cores: 60,
Insulator out diameter: ø1.25mm), Side connector
Approval
Unit weight Approx. 20g
Line-up
PNP output model
Question and Answer IconNeed help?

Do you have a question about the Autonics BF5R-D1-P and is the answer not in the manual?

Autonics BF5R-D1-P Specifications

General IconGeneral
Input Voltage12-24 VDC ±10%
Response TimeMax. 1 ms
Response Frequency500Hz
Output Current100mA max
Light SourceRed LED
Output ModeNPN
Protection CircuitReverse polarity protection
Ambient LightSunlight: Max. 11, 000 lx, Incandescent lamp: Max. 3, 000 lx
Storage Temperature-25 to 70°C
Ambient Humidity35 to 85% RH
MaterialABS
Isolation Voltage1, 500 VAC 50/60 Hz for 1 min
Humidity35 to 85% RH
Vibration Resistance1.5 mm amplitude at frequency of 10 to 55 Hz in each X, Y, Z direction for 2 hours
Shock Resistance500 m/s² (approx. 50 G) in each X, Y, Z direction for 3 times

Summary

Program Mode Settings

Parameter Initialization

Execute Parameter Initialization

Resets all parameters to default values, requiring the lock function to be OFF.

Sensitivity Setting Mode

Auto Tuning Teaching

Sets sensitivity using the average of max/min incident light levels, ideal for unstable or fast-moving objects.

Group Teaching

Master;Slave Unit Group Teaching

Sets slave unit sensitivity based on master unit command for collective, successive operation.

Data Bank Mode Flow

Data Load and Save

Manages loading and saving settings to/from Data Banks for group amplifier units.

Error Code Troubleshooting

Erb Error Code

Slave unit failure in communication; check connections and hardware.

Related product manuals