Safety Considerations
8
alarm lamp) where it can be seen from all sites.
For more information, please refer to laws, regulations and standards in the country or region.
35. -
ride function, set the time correctly according to the conditions described in this manual. In particular, set the
36.
37.
Calculate the safety distance suitable for the minimum detection capability to secure minimum safety distance.
38.
from entering the hazardous zone passing by beams for the blanking zone.
39.
40.
Calculate the safety distance suitable for the minimum detection capability to secure minimum safety distance.
41.
from entering the hazardous zone passing by beams for the blanking zone.
42. -
put temporarily goes to the OFF state.
Please note that the operating status of the light curtain may be changed.
43. If you use the reduced resolution function, the detection capability will be larger.
Calculate the safety distance suitable for the minimum detection capability to secure minimum safety distance.
44.
safety distance and the operation of the light curtain again.
45. Check ‘Connections’ before wiring. And make sure that there are no safety problems.
46. When using PNP output, be sure to connect the load between the OSSD output wire and 0V.
Do not short the OSSD output wires to +24V.
47. When using NPN output, be sure to connect the load between the OSSD output wire and +24V.
Do not short the OSSD output wires to 0V.
48. Use only the two OSSD output wires in this product to construct safety systems, and do not use output signals
49. When wiring, all input/output wires with double insulation or reinforced insulation should be used between
the circuits.
50. Do not install all input/output wires in the same piping with high voltage wire and power line.
Failure to follow this instruction may cause malfunction or dangerous due to the safety related function do not operate
properly.
51.