13
Do not place the intake opening of the air intake pipe in front of
the incoming air flow of the moving vessel
Fig. 7 - Installation of the air intake pipe
1 Air intake pipe;
4 Gasket;
2 Flange of the air intake pipe;
5 Fastener assembly;
3 Hull of the vessel;
6 Clamp.
3.3 Installation of the exhaust pipe.
When installing the exhaust pipe, take into
consideration high temperature (up to 500°С) of the
exhaust pipe when heater is in operation. Cut the exhaust
pipe (flexible crinkled metal hose, maximum length 2
meters) to the necessary length. It is advised to use two-
layer exhaust pipe when installing the heater. Attach the
exhaust pipe (Fig.8) using clamps and install it so that it is
slightly inclined to the bottom in the direction of exhaust.
Install heat insulation on the exhaust pipe to protect
individual sections of the vessel (wiring or other heat-
sensitive objects).
Fig. 8 - Attachment of the metal pipe to
the heater
Install the exhaust pipe to avoid the possibility of repeated intake of exhaust
gases by the air intake pipe, and make sure that no exhaust gases enter the
interior or are drawn in by the fan through the cab heater radiator.
At the end of the exhaust pipe a shield is installed, which necessary for stable
operation at low heating modes (Fig.9).