Remarks: yellow and green cord should be connected to connection point with mark.
z Fasten the fixture of wire to control panel.
z Screw up the control panel cover to its original place.
Test running
z Make sure that the pipes and wires are connected.
z Make sure that both the liquid valve and gas valve on the side are completely open.
1. The connection of power source
¾ Connect the wire to independent power source socket.
¾ Preparation of remote control.
¾ Run the air-conditioner in cooling operation mode for 30 minutes or longer.
2. Performance evaluation
¾ Test the out and in air temperature.
¾ Make sure that the temperature difference between the out and in air is greater than 8
o
C.