  • O
    ogrimesSep 23, 2025
    What does F4 error mean on AUX Air Conditioner?
    • M
      Mrs. Mary FisherSep 23, 2025
      If your AUX Air Conditioner displays error code F4, it indicates an exhaust sensor error. This occurs when the outdoor unit main PCB detects a short circuit or open circuit in the exhaust sensor. Check if there is any evident resistance problem in the sensor.
  • N
    nathanklineAug 23, 2025
    How to fix F6 error on AUX ASW-H18E3B4/FAR3DI-C0?
    • C
      Charlene RichardsonAug 23, 2025
      If your AUX Air Conditioner displays error code F6, it indicates an outdoor unit temperature sensor error. This is detected as a short circuit or open circuit during the outdoor unit main PCB's inspection. Check whether there’s resistance problem, short circuit or open circuit in the sensor; the resistance value shall be within a reasonable range (15K? under the temperature of 25?).
  • C
    Christina VincentAug 25, 2025
    How to troubleshoot E2 error on AUX ASW-H18E3B4/FAR3DI-C0 Air Conditioner?
    • L
      lewisjohnAug 26, 2025
      If your AUX Air Conditioner displays error code E2, it indicates an outdoor unit coil sensor error. This is detected as a short circuit or open circuit during the inspection of the outdoor unit's main PCB. Check whether there’s resistance problem, short circuit or open circuit in the sensor; the resistance value shall with a reasonable range (about 20K? for frequency conversion machine).
  • H
    Hector AndersonAug 26, 2025
    How to troubleshoot E3 error on AUX ASW-H18E3B4/FAR3DI-C0 Air Conditioner?
    • W
      Wesley GonzalezAug 27, 2025
      If your AUX Air Conditioner displays error code E3, it indicates an indoor unit coil sensor error. This is detected as a short circuit or open circuit during the inspection of the indoor unit's main PCB. Check whether there’s resistance problem, short circuit or open circuit in the sensor; the resistance value shall with a reasonable range (about 20K? for frequency conversion machine).
  • R
    ricardohamiltonAug 27, 2025
    What to do if AUX Air Conditioner shows E0 error?
    • M
      Miranda LoweAug 27, 2025
      If your AUX Air Conditioner displays error code E0, it means the main PCB has detected that the system's working current is too high, triggering overcurrent protection. As a result, the air conditioner will stop running. To resolve this, inspect the current transformer, power line, compressor line, and connector assembly.
  • N
    ngarciaSep 16, 2025
    What causes F3 error on AUX ASW-H18E3B4/FAR3DI-C0 Air Conditioner?
    • L
      Lisa LangSep 16, 2025
      An F3 error on your AUX Air Conditioner indicates a compressor out-of-step error. The module panel constantly tests the current of lead wires of the compressor and calculates the position of the rotator of the compressor when driving the compressor to work. Check if the order of compressor wires is incorrect, which makes the compressor rotate reversely.
  • C
    Caleb DavisSep 13, 2025
    Why AUX Air Conditioner shows P4 error?
    • D
      David JamesSep 13, 2025
      If your AUX Air Conditioner displays error code P4, it indicates refrigeration overload protection. This happens when the outdoor coil sensor senses excessive temperature, preventing the compressor from overloading and reducing frequency. Check the coil sensor with a multimeter to see if the resistance value is normal (20K? standard sensor, 25?).
  • C
    Catherine SilvaSep 14, 2025
    What does P3 error mean on AUX Air Conditioner?
    • D
      Diane MyersSep 15, 2025
      If your AUX Air Conditioner displays error code P3, it indicates Liquid Deficiency Protection. This happens when the liquid volume of the system is less than 30%, which leads to non-refrigeration and liquid shortage protection. Check the stop valve and turn it counterclockwise with hexagons to see if the valve is not open and the opening is not enough.
  • R
    Ricky StewartSep 5, 2025
    What does F8 error mean on AUX ASW-H18E3B4/FAR3DI-C0 Air Conditioner?
    • S
      Samuel MccoySep 5, 2025
      If your AUX Air Conditioner displays error code F8, it indicates a communication error between the outdoor unit's main PCB and the module panel. This occurs when the normal communication between these components is disrupted during operation. First, check if the communication connection line (mostly 4 chips) between the module panel and main control panel is loose.
  • E
    Emily BaileySep 3, 2025
    What does P8 error mean on AUX ASW-H18E3B4/FAR3DI-C0 Air Conditioner?
    • T
      Todd LopezSep 3, 2025
      If your AUX Air Conditioner displays error code P8, it means that the controller has detected the AC bus current exceeding the set protection value, triggering overcurrent protection. As a result, the frequency is limited and reduced. To resolve this, use a multimeter to detect and check if the bus voltage is too low.

Summary

Part I: Technical Information

1. Summary

Overview of product features, appearance, and model lineup.

3. Function and Control

Explains operational modes, settings, and remote controller functions.

2. Outline Dimension Diagram

Provides detailed physical dimensions and graphical representations of the unit.

4. Refrigerant System Diagram

Illustrates refrigerant flow for cooling and heating cycles.

5. Electrical Part

Details electrical specifications, wiring diagrams, and power requirements.

Part II: Installation and Maintenance

6. Main Tools for Installation and Maintenance

Lists and illustrates essential tools required for installation and maintenance tasks.

7. Installation

Step-by-step instructions and important notes for installing the air conditioner unit.

8. Maintenance

Guides for troubleshooting common issues and error codes.

9. Exploded Views and Parts List

Detailed diagrams showing unit components and a list of parts with their numbers.

10. Removal Procedure

Instructions for safely disassembling and removing unit components.

Appendix

AUX Common Sensor R-T Analysis Table

Data table correlating sensor resistance with temperature and MCU input voltage.

AUX ASW-H18E3B4/FAR3DI-C0 Specifications

General IconGeneral
Cooling Capacity18000 BTU/h
Energy Efficiency Ratio (EER)3.21
Power Supply220-240V, 50Hz
RefrigerantR410A
Weight (Outdoor Unit)34 kg
TypeSplit Type
Outdoor Unit Dimensions (W x H x D)800 x 545 x 315 mm
Operating Temperature (Cooling)18-43°C