temperature reaches more than the temperature set plus 1while the
condition on which the compressor shuts down is that the indoor
temperature reaches less than the temperature set minus 1.And
when the indoor temperature is equal to that set, the original
operation mode will be kept.
3.4 Under the mode of refrigeration, the function of preventing indoor
coiled pipe from being frozen will be effective.
3.5 The indoor wind speed will be as set. And the pendulum leaves will
work according to the instructions sent by remote control.
4. Dehumidification operation
4.1 The temperature range set and controlled is between 16and 32.
The temperature will be set by remote control.
4.2 The four-way valve is shut down.
4.3 The wind speed gear-changes to “mute". And the pendulum leaves
works according to the instructions sent by remote control;
4.4 The function of preventing indoor coiled pipe from being frozen is
effective.
4.5 When the indoor temperature reaches less than 16, the function of
dehumidification is out of use.
4.6 When the indoor temperature reaches more than 16 , the
compressor will be switched on and work intermittently. The time
when the compressor shuts down depends on T ring and T ring-T set.