EasyManua.ls Logo

Ava Master P80 - Troubleshooting

Default Icon
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AVA Pressure washer P60/P70 / P80
| 13
Troubleshooting
Problem Possible Cause Corrective Action
Motor refuses to
start
Plug not connected Connect plug
Mains socket faulty Use another socket
Fuse faulty/blown Replace fuse
Extension cable dam-
aged
Try without extension cable
Motor protector has
activated
Allow to cool for 15 minutes
Frozen "Wait for pump/water supply
hose/accessory to Thaw"
Motor stops Fuse faulty/blown Replace fuse
Wrong mains voltage "Check that mains voltage
corresponds to specifications
on the model tag"
Motor protector has
activated
Allow to cool for 15 minutes
Fuses blow Fuses incorrectly rated "Change to a mains supply
higher than the pressure
washer amp consumption"
Motor starts but
no pressure
Nozzle partly blocked Clean nozzle
Motor “sounds”
but fails to start
Insufficient power supply "Check that the voltage of the
mains power supply line is the
same as that on the plate"
"Voltage loss due to use
of extension Cable"
Check characteristics of
extension cable
"Appliance not used for
a long period of time"
Contact AVA/retailer
"Problems with TSS (To-
tal Stop System) device"
Contact AVA/retailer
Pressure pulsat-
ing
"Air in the inlet water
supply hose/pump"
"Allow pressure washer to run
with open spray handle and
nozzle at low pressure until
regular working pressure is
obtained"
English