Specifications 5
Travis Industries Newport 290902
Heating Specifications:
Approximate Maximum Heating Capacity (in square feet)*.................................800 to 1,600 Sq. Feet
Burn Rate (Pounds per Hour)**.......................................................................1.0 to 3.5
Maximum Burn Time on Low Burn** ................................................................15 - 50 Hours
Hopper Capacity............................................................................................55 Pounds
* Heating capacity will vary depending on the home's floor plan, degree of insulation, and the outside
temperature. It is also affected by the fuel size, quality, and moisture level.
** Small pellets will increase or decrease the stated burn rates and burn times. Differences of plus or minus 20%
depending on fuel quality may occur.
Dimensions:
Air Inlet
(1-3/4"
Outside
Diameter)
AA
AA
29-1/2"
20-7/8"
21-5/8"
16-7/8"
10-3/4"
7-5/8"
5-5/8"
Weight: 175 Lbs.
3" Diameter
Exhaust
Electrical Specifications:
Electrical Rating.........................................................................................115 Volts, 3.6 Amps, 60 Hz
Watts During Start-Up Sequence...................................................................400 (approximately)
Watts During Operation ...............................................................................180 (approximately)
Fuel:
The unit is designed for wood pellets that comply with the standards set by the Association of Pellet Fuel
Industry (density of at least 40 lbs. per cubic foot, 1/4" to 5/16" diameter, length no greater than 1–1/2", 8200
BTU's/lb., moisture under 8% by weight, ash under 1% by weight, and salt under 300 parts per million). If the fuel
does not comply to this standard, the unit may not operate as designed.
EPA Compliance:
This heater is EPA exempt from Phase II requirements, but has been tested for emissions using EPA test
methods by OMNI Test Labs.