    Why Avalon Rainier 945 Stove does not burn hot enough?
    • J
      Jenna BradySep 10, 2025
      There are several reasons why your Avalon stove might not be burning hot enough. * The wood may be wet. Refer to the "Selecting Wood" section on page 29 for more information. * Insufficient draft can be a factor. Chimney height and outside conditions can negatively affect the draft, causing the fire to burn slowly. Adding more pipe or a draft-inducing cap might help. * The air control might not be fully open. Ensure the air control is all the way in and slide it back and forth to make sure it is not stuck.
  • J
    Janet CantrellAug 22, 2025
    Why is my Avalon Rainier 945 Stove not burning hot enough?
    • B
      brittany56Aug 22, 2025
      If your Avalon Stove isn't burning hot enough, several factors could be at play. First, ensure your wood is dry; refer to the "Selecting Wood" section on page 27 for guidance. Insufficient draft can also cause this issue; adding more pipe or a draft-inducing cap might help. Lastly, verify that the air control is fully open and not stuck by sliding it back and forth.
  • A
    Alyssa MoodyAug 25, 2025
    What to do if smoke enters the room while reloading my Avalon Stove?
    • D
      Dennis RiveraAug 25, 2025
      If smoke enters the room while reloading your Avalon Stove, allow the air to stabilize before fully opening the door. Push the air control in before opening the door, then open the door about an inch to let air into the firebox for a few seconds. Once the smoke consistently flows up the chimney, fully open the door. Insufficient draft may also be the cause, so adding more pipe or a draft-inducing cap might help.
  • L
    Lindsay RobertsonAug 26, 2025
    How to stop smoke from entering the room during Avalon Rainier 945 Stove start-up?
    • A
      Allison WattsAug 26, 2025
      If smoke enters the room during the start-up of your Avalon Stove, it could be due to a cold air blockage. Try burning a piece of newspaper to establish a draft. Also, ensure the air control is fully open (all the way in). If more air is needed, slightly crack the door open.
  • J
    Jessica MillerAug 27, 2025
    Why doesn't my Avalon Rainier 945 burn long enough?
    • H
      Hannah SmithAug 28, 2025
      If your Avalon Stove isn't burning long enough, ensure the doors are sealing properly to prevent air from entering the firebox; see the "Door and Glass Inspection" section on page 30 for details. Also, check the ash bed for coals, which may be glowing under a layer of flyash. Raking these coals into a pile can help restart the stove quickly.
  • K
    Katie CarterAug 29, 2025
    What to do if kindling does not start in my Avalon Stove and fire smolders?
    • M
      Mark ClarkAug 29, 2025
      If the kindling in your Avalon Stove isn't starting and the fire smolders, it might be due to a cold air blockage. Try burning a piece of newspaper to establish a draft. If needed, use additional newspaper. Also, make sure the air control is fully open. If more air is required, slightly crack the door open.
  • J
    james37Sep 18, 2025
    Why doesn't the blower run on my Avalon Stove?
    • K
      Katherine RoseSep 18, 2025
      If the blower on your Avalon Stove isn't running, it could be due to a couple of reasons. First, the stove might not be hot enough yet; the blower typically activates after 15 to 30 minutes of operation. Another cause could be an interruption in the electricity supply to the blower. Check your household breaker or fuse to ensure it's working correctly.
  • H
    hmartinSep 12, 2025
    How to stop smoke entering the room during Avalon Stove start-up?
    • P
      pedwardsSep 12, 2025
      If smoke enters the room during the start-up of your Avalon stove, it could be due to a cold air blockage. To resolve this, burn a piece of newspaper to establish a draft. Also, ensure the air control is fully open. If more air is needed, slightly crack the door.
  • L
    lewisparkerSep 8, 2025
    Why doesn't the blower run on my Avalon Wood stove?
    • S
      samanthasolisSep 8, 2025
      The blower on your Avalon Wood stove might not be running because the stove hasn't reached the required temperature yet; the blower usually activates after 15 to 30 minutes. Also, check the household breaker or fuse to ensure electricity is flowing to the blower.
  • H
    Harry PerkinsSep 5, 2025
    What to do if the kindling does not start and the fire smolders in my Avalon Wood stove?
    • M
      Mitchell MaySep 5, 2025
      If the kindling in your Avalon Wood stove isn't starting and the fire is smoldering, it could be due to a cold air blockage; try burning a piece of newspaper to establish a draft. Also, ensure you're using enough starter paper; add more newspaper if needed. Make sure the air control is fully open, and if additional air is needed, slightly crack the door.

Avalon Rainier 945 Specifications

General IconGeneral
Fuel TypeWood
Efficiency75.7% (LHV)
MaterialSteel
EPA CertifiedYes
Heating Capacity1, 200 - 2, 200 sq ft