Commercial Refrigerator
Users Manual
- 1 -
User Manual
Please read the manual thoroughly prior to equipment set-up,
operation and maintenance.
10/2020
Refrigerated Pizza Prep Units
178SSPPT1, 178SSPPT2, 178SSPPT260, 178SSPPT3
Refrigerated Sandwich Prep Units
178SSPT27HC, 178SSPT36HC, 178SSPT48HC, 178SSPT60HC,
178SSPT71HC, 178SSPT27MHC, 178SSPT36MHC, 178SSPT48MHC,
178SSPT60MHC, 178SSPT71MHC

Questions and Answers

  • D
    David HallAug 19, 2025
    Why is my Avantco 178SSPT48MHC Refrigerator's cabinet temperature too warm?
    • S
      Shannon GilbertAug 19, 2025
      There are several reasons why your Avantco Refrigerator's cabinet temperature might be too warm: * The thermostat is set too high: Lower the thermostat temperature. * Airflow is blocked: Re-arrange products to allow for proper airflow. * Too much warm product was placed inside: Allow adequate time for the product to cool down. * A fuse is blown or the circuit breaker tripped: Replace the fuse or reset the circuit breaker. * The condenser coil is dirty: Clean the condenser coil. * The evaporator coil is iced over: Ensure doors are closed when not in use. * Refrigerant levels are low: Contact a service technician to check refrigerant levels. * The door is slightly ajar: Make sure the doors are completely closed.
  • J
    Joseph GrossAug 21, 2025
    Why is my Avantco 178SSPT48MHC compressor not running?
    • A
      Alison GatesAug 21, 2025
      If the compressor in your Avantco Refrigerator isn't running, several factors could be the cause. It could be due to a blown fuse or tripped circuit breaker, so replace the fuse or reset the breaker. Another reason might be that the power cord is unplugged, so ensure it's properly plugged in. Also, check the thermostat setting; if it's set too high, lower the temperature. Lastly, the refrigerator might be in a defrost cycle, so wait for it to finish.
  • S
    Sydney DiazAug 25, 2025
    Why does my Avantco 178SSPT48MHC's condensing unit run for long periods of time?
    • L
      lisa58Aug 25, 2025
      Your Avantco Refrigerator's condensing unit might run for extended periods due to: 1. An excessive amount of warm product placed inside: Allow adequate time for the product to cool down. 2. Prolonged door opening or the door being ajar: Ensure doors are closed when not in use. 3. Door gasket(s) not sealing properly: Ensure gaskets are snapped in completely. 4. A dirty condenser coil: Clean the condenser coil. 5. Evaporator coil iced over: Unplug the unit and allow the coil to defrost. 6. Thermostat set too cold: Ensure that door gasket(s) are sealing properly.
  • A
    Amanda SmithAug 26, 2025
    What to do if I placed too much warm product in my Avantco Refrigerator?
    • M
      Mark BradyAug 26, 2025
      If you've placed an excessive amount of warm product in your Avantco Refrigerator, allow adequate time for the product to cool down.
  • S
    Shannon NelsonAug 28, 2025
    What to do if the Avantco 178SSPT48MHC compressor is not running?
    • J
      Jonathan GardnerAug 28, 2025
      If the compressor on your Avantco Refrigerator isn't running, check the following: * A blown fuse or tripped circuit breaker: Replace the fuse or reset the circuit breaker. * The power cord might be unplugged: Plug in the power cord. * The thermostat might be set too high: Set the thermostat to a lower temperature. * The cabinet might be in defrost cycle: Wait for the defrost cycle to finish.
  • M
    Maria CoxAug 30, 2025
    How to stop condensation collecting on my Avantco 178SSPT48MHC cabinet or floor?
    • S
      Sheila HahnAug 30, 2025
      If you notice condensation collecting on your Avantco Refrigerator's cabinet or floor, it could be due to: * The gasket not sealing properly: Clean, repair, or replace the gasket as necessary. * Relative humidity being above 60%: Move the unit to an area with lower relative humidity or lower the humidity level.
  • E
    erinherreraSep 1, 2025
    What to do if the evaporator coil is iced over in my Avantco 178SSPT48MHC?
    • J
      Jessica WarnerSep 1, 2025
      If the evaporator coil in your Avantco Refrigerator is iced over, unplug the unit and allow the coil to defrost. Also, make sure the thermostat is not set too cold and ensure that the door gaskets are sealing properly.
  • J
    Joel GutierrezSep 3, 2025
    How to fix Avantco 178SSPT48MHC door gaskets not sealing properly?
    • A
      Alan FletcherSep 3, 2025
      To address door gaskets that are not sealing properly on your Avantco Refrigerator: First, ensure the gaskets are snapped in completely. If not, remove the gasket and wash it with soap and water. After cleaning, check the condition of the gasket, and replace it if necessary.
  • A
    Amy ArmstrongSep 5, 2025
    What to do if the Avantco 178SSPT48MHC Refrigerator door was opened for too long?
    • C
      Carolyn BrownSep 5, 2025
      If you're experiencing issues related to prolonged door opening or a door left ajar on your Avantco Refrigerator, ensure the doors are closed when not in use. Avoid opening the doors for extended periods.
  • J
    Jordan DavisSep 7, 2025
    What to do if my Avantco Commercial Food Equipment is not working?
    • A
      Amber WrightSep 7, 2025
      If your Avantco Commercial Food Equipment isn't working, first, ensure it's properly plugged into a power supply and that the control knob is turned away from the “OFF” position. Check if the circuit breaker has tripped and reset it if necessary. If these steps don't resolve the issue, there may be a defective control knob or internal thermostat, or the heating element could be burned out, in which case you should contact an authorized electrician.

Summary

Warning

Installation

Cabinet Location Guidelines

Recommendations for choosing an optimal installation site, considering surface, ventilation, and environmental factors.

Electrical

Temperature Controls

Functions

Adjusting the Temperature

Step-by-step instructions for modifying the minimum temperature setting using the digital control unit's buttons.

Safety; Warning

Regular Maintenance

Troubleshooting

Compressor Not Running

Potential causes and solutions for the compressor not running, such as electrical issues or thermostat settings.

Condensing Units Run For Long Periods of Time

Troubleshooting steps for units where the condensing unit runs excessively, including airflow and door seal checks.

Cabinet Temperature is too Warm

Solutions for warm cabinet temperatures, covering thermostat settings, airflow obstruction, and coil condition.