Commercial Refrigerator
Users Manual
- 1 -
User Manual
Please read the manual thoroughly prior to equipment set-up,
operation and maintenance.
10/2020
Refrigerated Pizza Prep Units
178SSPPT1, 178SSPPT2, 178SSPPT260, 178SSPPT3
Refrigerated Sandwich Prep Units
178SSPT27HC, 178SSPT36HC, 178SSPT48HC, 178SSPT60HC,
178SSPT71HC, 178SSPT27MHC, 178SSPT36MHC, 178SSPT48MHC,
178SSPT60MHC, 178SSPT71MHC

Questions and Answers

  • A
    Allen DunnAug 19, 2025
    Why is my Avantco 178SSPT60MHC Refrigerator's cabinet temperature too warm?
    • R
      rachael57Aug 19, 2025
      There are several reasons why your Avantco Refrigerator's cabinet temperature might be too warm: * The thermostat is set too high: Lower the thermostat temperature. * Airflow is blocked: Re-arrange products to allow for proper airflow. * Too much warm product was placed inside: Allow adequate time for the product to cool down. * A fuse is blown or the circuit breaker tripped: Replace the fuse or reset the circuit breaker. * The condenser coil is dirty: Clean the condenser coil. * The evaporator coil is iced over: Ensure doors are closed when not in use. * Refrigerant levels are low: Contact a service technician to check refrigerant levels. * The door is slightly ajar: Make sure the doors are completely closed.
  • R
    Rebecca StephensAug 21, 2025
    Why is my Avantco 178SSPT60MHC compressor not running?
    • R
      rloveAug 21, 2025
      If the compressor in your Avantco Refrigerator isn't running, several factors could be the cause. It could be due to a blown fuse or tripped circuit breaker, so replace the fuse or reset the breaker. Another reason might be that the power cord is unplugged, so ensure it's properly plugged in. Also, check the thermostat setting; if it's set too high, lower the temperature. Lastly, the refrigerator might be in a defrost cycle, so wait for it to finish.
  • A
    Amber RomeroAug 23, 2025
    Why does my Avantco Refrigerator's condensing unit run for long periods of time?
    • G
      gillmarciaAug 23, 2025
      Your Avantco Refrigerator's condensing unit might run for extended periods due to: 1. An excessive amount of warm product placed inside: Allow adequate time for the product to cool down. 2. Prolonged door opening or the door being ajar: Ensure doors are closed when not in use. 3. Door gasket(s) not sealing properly: Ensure gaskets are snapped in completely. 4. A dirty condenser coil: Clean the condenser coil. 5. Evaporator coil iced over: Unplug the unit and allow the coil to defrost. 6. Thermostat set too cold: Ensure that door gasket(s) are sealing properly.
  • R
    Rachel SnyderAug 26, 2025
    What to do if I placed too much warm product in my Avantco Refrigerator?
    • T
      tprattAug 26, 2025
      If you've placed an excessive amount of warm product in your Avantco Refrigerator, allow adequate time for the product to cool down.
  • B
    Bryan HughesAug 27, 2025
    What to do if the Avantco 178SSPT60MHC compressor is not running?
    • A
      Angela SparksAug 28, 2025
      If the compressor on your Avantco Refrigerator isn't running, check the following: * A blown fuse or tripped circuit breaker: Replace the fuse or reset the circuit breaker. * The power cord might be unplugged: Plug in the power cord. * The thermostat might be set too high: Set the thermostat to a lower temperature. * The cabinet might be in defrost cycle: Wait for the defrost cycle to finish.
  • C
    Casey QuinnAug 29, 2025
    How to stop condensation collecting on my Avantco Refrigerator cabinet or floor?
    • S
      Steven SalinasAug 29, 2025
      If you notice condensation collecting on your Avantco Refrigerator's cabinet or floor, it could be due to: * The gasket not sealing properly: Clean, repair, or replace the gasket as necessary. * Relative humidity being above 60%: Move the unit to an area with lower relative humidity or lower the humidity level.
  • A
    Alexandra MortonAug 31, 2025
    What to do if the evaporator coil is iced over in my Avantco 178SSPT60MHC Refrigerator?
    • H
      hbrownSep 1, 2025
      If the evaporator coil in your Avantco Refrigerator is iced over, unplug the unit and allow the coil to defrost. Also, make sure the thermostat is not set too cold and ensure that the door gaskets are sealing properly.
  • M
    meganthompsonSep 3, 2025
    How to fix Avantco 178SSPT60MHC door gaskets not sealing properly?
    • S
      Stephanie ChandlerSep 3, 2025
      To address door gaskets that are not sealing properly on your Avantco Refrigerator: First, ensure the gaskets are snapped in completely. If not, remove the gasket and wash it with soap and water. After cleaning, check the condition of the gasket, and replace it if necessary.
  • G
    George RobertsSep 5, 2025
    What to do if the Avantco 178SSPT60MHC Refrigerator door was opened for too long?
    • C
      Calvin Contreras DDSSep 5, 2025
      If you're experiencing issues related to prolonged door opening or a door left ajar on your Avantco Refrigerator, ensure the doors are closed when not in use. Avoid opening the doors for extended periods.
  • P
    Paula McdowellSep 7, 2025
    What to do if my Avantco Commercial Food Equipment is not working?
    • R
      Rebecca WrightSep 7, 2025
      If your Avantco Commercial Food Equipment isn't working, first, ensure it's properly plugged into a power supply and that the control knob is turned away from the “OFF” position. Check if the circuit breaker has tripped and reset it if necessary. If these steps don't resolve the issue, there may be a defective control knob or internal thermostat, or the heating element could be burned out, in which case you should contact an authorized electrician.

Summary

Safety Warnings

Fire and Explosion Hazards

Dangers of fire or explosion due to flammable refrigerant and potential tubing puncture.

Installation Guidelines

Pre-Installation Checklist

Crucial steps before installing the unit, including shelf setup, standing time, and ventilation.

Electrical and Temperature Controls

Electrical Requirements

Proper grounding, dedicated outlets, and avoiding extension cords for safe electrical connection.

Temperature Adjustment Procedure

How to adjust the minimum temperature using the digital control unit and understanding temperature fluctuations.

Operation and Defrost

General Safety Precautions

Electrical Safety and Handling

Guidelines on outlet usage, extension cords, unplugging, and avoiding hazards.

Operational Warnings

Important warnings about unit operation, maintenance, and personal safety, including door use and storage.

Regular Maintenance and Cleaning

Condenser Coil Cleaning

Instructions for cleaning the condenser coil and fins for optimal operation.

Interior Cleaning Procedures

Steps for cleaning the unit's interior, door gaskets, shelves, and pilasters.

Food Pan Divider Bar Specifications

Troubleshooting Guide

Compressor Issues

Potential causes and solutions for the compressor not running.

Unit Running Time Problems

Troubleshooting for condensing units running for extended periods.

Cabinet Temperature Problems

Causes and solutions for the cabinet temperature being too warm.

Warranty Information

Warranty Service and Special Use

Avantco 178SSPT60MHC Specifications

General IconGeneral
BrandAvantco
Model178SSPT60MHC
CategoryRefrigerator
LanguageEnglish