Page 10 of 11
Eddie Jones / Mike Freitas 9329-65762-00 REV A 09/16 Avid©2016
8. In the window that appears, configure the settings as shown in the image on the right below and
press OK. Close all the other windows.
9. On the second S6 Master Module, follow steps 4 to 8 above to set its port 2 to IP manual address
to 192.168.3.2 subnet 255.255.255.0.
10. Now power on all your Workstations and follow the instructions from item 3 above to set their IP
Addresses to 192.168.3.4, 192.168.3.5 etc. subnet always 255.255.255.0
11. Power cycle both S6 systems and the Workstations but not the Router.
12. The Master Modules will boot into the S6 software. If both the WAN and S6 networks are seen, a
warning appears telling you to set the correct network port for S6.
If it does not appear, logout of S6, wait a few seconds (for the networks to come up) and log back
into S6User again.
13. On both Master Modules go to Settings > Surface, and open its Local Options screen (gear icon).
14. Select the S6 Network Adapter, it will have the IP address we set earlier 192.168.3.1 on the first
Master Module and 192.168.3.2 on the second Master Module.
15. Now power cycle both S6 systems and the Workstations but not the Router one last time.
16. To add the IHSE Ethernet KVM follow the instruction provided with it to set its network to the
correct settings to work on the WAN.
17. Follow the S6 Guide and enter its IP address into the Master Modules KVM settings screen.