2.2 Specification
⚫ Power input : 100 - 240VAC , 50-60Hz ,
⚫ Maximum loading of each output: 10A
⚫ Maximum of Total loading : 10A / 240VAC , 15A / 100VAC
⚫ Fuse protection : 10A / 250VAC ( with spare fuse in socket )
⚫ Dimensions: 195 x 116 x 45 mm ( L x W x H )
⚫ Weight: 1 kg
⚫ Enclosure – Matel case in blue color
⚫ Operation Temperature : - 15°C ~ 60°C or 5°F~ 140 °F
⚫ INLET
Input plug
IEC 320 C14 . 50 - 60Hz
Voltage
100-240VAC Auto sensing
Maximum input current
10 Amp
Protection
Fuse 250VAC 10 Amp
( removable with spare one in socket )
⚫ OUTLET
Output plug
IEC 320 C13 * 4 - individually switched
Maximum current per outlet
10 Amp
Total current
10 Amp
Overoad protection
Fuse 10ª / 250VAC
⚫ PHYSICAL & ENVIRONMENT
Dimention (WxDxH)
195 x 116 x 45 mm
Unit Weight
1 kg
Operating Temperature
- 15°C ~ 60°C or 5°F~ 140 °F
Regukatory Approvals
CE ( LVD )
Warranty
Standard 1 year
2.3 Minimum System Requirements
Web Browser of WINDOWS / iOS / Android : Google Chrome , Safari , IE and so on .
Network connection for Internet connection .
Internet HUB & Switch ( with RJ45 port)