AXIS2911UVideoServerRack
RS485/RS422Connector
TwoterminalblocksforRS485/RS422serialinterfaceusedtocontrolauxiliaryequipmentsuch
asPTZdevices.
Specications
OperatingConditions
TheAxisproductisintendedforindooruse.
ProductTemperatureHumidity
AXIS2911U0°Cto45°C
(32°Fto113°F)
20-80%RH(non-condensing)
PowerSpecications
NO NO
NO
TICE TICE
TICE
Usealimitedpowersource(LPS)witheitheraratedoutputpowerlimitedto≤100W
oraratedoutputcurrentlimitedto≤5A.
ProductInputVoltage
InputCurrentPowerConsumption
AXIS2911U100–240VAC
50–60Hz
1.9A
With3AXIS243Q:max.80W
Connectors
PowerConnector
ACconnectorforpowerinput.
Powercordplugvariants: