AXISD2050-VENetworkRadarDetector
Setup
Therearetwotypesofzones:
Anincludezoneisanareainwhichmovingobjectswilltriggeractionrules.Thedefaultincludezonematchesthe
entireareacoveredbythedetector.
Anexcludezoneisanareainwhichmovingobjectswillbeignored.Useexcludezonesifthereareareasinsideaninclude
zonethattriggeralotofunwantedalarms.
Addanincludezone
1.GotoSettings>RMDzonesandclick
2.SelectIncludezone.
3.Select
tomodifythesettingsofthezone.Formoreinformation,seetheproduct’sbuiltinhelp.
4.Modifytheshapeoftheincludezone,seeModifyadetectionzoneonpage12
Addanexcludezone
1.GotoSettings>RMDzonesandclick
2.SelectExcludezone.
3.Modifytheshapeoftheexcludezone,seeModifyadetectionzoneonpage12
Modifyadetectionzone
Usethemousetomoveandshapethezonesothatitcoversthedesiredpartofthereferencemap.
Toaddanewcorner,clickonthezoneborder.Dragthecornertothedesiredposition.
Toremoveacorner,right-clickonthecorner.
Tomoveacorner,clickanddragthecornertothenewposition.
Tomovethezone,placethepointerinsidethezoneanddragthezonetothenewposition.
Howtominimizefalsealarms
Ifyounoticethatyougettoomanyfalsealarms,youcanlteroutcertaintypesofmovementorobjects,orchangethecoverage.
Testwhichsettingworksbestforyourenvironment.
Modifytheincludeandexcludezones:
Iftheincludezoneincludeshardsurfaces,suchasametalwall,theremaybereectionsthatcausesmultipledetectionsfor
asinglephysicalobject.Inthiscase,modifytheincludezone,seeModifyadetectionzoneonpage12,oraddanexclude
zonethatmaskseverythingbehindthesurface,seeAddanexcludezoneonpage12
Filteronmovement:
GotoSettings>Radar>DetectionandselectIgnoreswayingobjects.Thissettingwillminimizefalsealarmsfromtrees,
bushes,andagpolesinthecoveragezone.
Filterontime:
GotoSettings>RMDzonesandselectazonetomodifyit’ssettings.
EnableShort-livedobjectandsetadelaytimefromwhentheradarstartstrackinganobjectuntilitcantriggerandalarm.
Thetimerstartswhentheradarrstdetectstheobject,notwhentheobjectenterstheincludezone.