AXISD2050-VENetworkRadarDetector
Productoverview
Mountingdirection
Thedetectorcoversanangleof±60°fromitscentralaxis.Thismeansthatifyoumountitonawallthereisablindspottoeach
sideofthedetector.
Tocoverthewallyoucanmovetheradarmoduleinsidethedetector.
1
-25°mountingdirection
2
mountingdirection
3
25°mountingdirection
Mountingheight
Foroptimalperformance,installthedetector3.5m(11ft)aboveground.
Note
Ifyouinstallthedetectoratadifferentheight,entertheactualmountingheightintheproduct’swebpagesbefore
calibratingtheradar.
Thefollowingtableshowsthedetectionrangeatdifferentmountingheightswhendetectinga1.8m(6ft)tallpersonwalking.
Mountingheight
3.5m(11ft)4m(13ft)4.5m(15ft)5m(16ft)
Neardetectionlimit
4.5m(15ft)6m(20ft)7m(23ft)8.5m(28ft)
Fardetectionlimit(max.values)49m(161ft)51m(167ft)51m(167ft)52m(171ft)