EasyManua.ls Logo

Axis Q8741-E - Cable Thickness; Operating Conditions; Power Consumption

Axis Q8741-E
184 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AXISQ87BispectralPTZNetworkCameraSeries
Position
24VAC24VDC
1
ProtectiveearthProtectiveearth
2
24VACPhase
+24V
3
24VACNeutral
0V
4
NotconnectedNotconnected
Cables
Cablethickness
Thecablediameter,whenusingcablegasketsprovidedwiththeproduct,shouldbeintherangeof
5to11mm(0.2to0.4in).
NO NO
NO
TICE TICE
TICE
Usecablesthatkeepwithinthespeciedcablearea
Selectcablesincompliancewithyourlocalregulations
Makesureallcableholesareproperlysealed
Usecablegasketsorcableglandsthatmatchboththecableholeandthecablearea
Forinformationaboutaccessories,suchascablegasketsandcableglandsthatallowforother
cableareas,seewww.axis.com
Operatingconditions
TheAxisproductisintendedforindoorandoutdooruse.
TemperatureHumidity
Operatingtemperature:-50°Cto55°C
(-58°Fto131°F)
ColdStartup(<1hstartuptime,tofully
functional):-40°C(-40°F)
10–100%RH(non-condensing)
Powerconsumption
ProductTypicalconsumptionMaxconsumption
AXISQ8741-E24VAC/DC
AXISQ8742-E24VAC/DC
16W204W
30

Table of Contents

Other manuals for Axis Q8741-E

Related product manuals