AXIST815460WSFPMidspan
Troubleshooting
SymptomCorrectiveaction
Unplugandthenre-plugthemidspan’spower
cableandcheckthepowerLEDindicatorstatus
duringthepower-upsequence.
Verifythatthepowerinletvoltageisbetween
100–240VAC.
Themidspandoes
notpowerup
Verifythatthepowerinletcableis
intact/functional.
VerifythattheremotedeviceisdesignedforPoE
operation.
Verifythattheremotedeviceisconnectedto
themidspan’sDATAPWROUTportusinga
standardSTPCAT5orhigher,straight-wired
networkcablewithfourpairs.
Ifanexternalpowersplitterisinuse,verifythat
itworks.
Verifythatthereisnoshortcircuitonanyofthe
twistedpaircablesorRJ45connectors.
Theremotedevice
connectedtothe
midspandoesnot
powerup
Ifpossible,connecttheremotedevicetoa
differentmidspan.
15