・Concerning setting and adjustment of the timer; 
In case of the lubrication unit without electrical control circuit, refer to the instructions 
attached to the interval timer that was separately prepared by the user. 
・Timer for interval activation of pump is not equipped to the standard MC9 lubrication 
unit.   
 
7-5. Method of Setting of Oil-Shot Frequency 
・Timer frequency rate must be set at same rate with the oil drips per minute. However in case the 
first operations after installation, or after maintenance, supply more oil than required for usual 
lubrication. And the machine should be started from slower speed than the normal operation 
speed.   
・Setting of the interval operation timer should be below 20 times per minute in case of normal 
lubrication operation. 
 
In case of lubrication units with electrical 
control circuit     
・Oil shots rate (shots/min) can be set by 
the shot interval from 
combination of ON position of DIP 
Switch on the control circuit board. 
・Use following DIP Switch combination 
table for setting of oil shot quantities, 
that can be set from oil shot interval 
based on DIP Switch combination.