◇  Model Numbers 
 
D04 Filter-Regulator, 
or D14 Regulator 
 
Oil Drip Monitor 
or 
Oil Feed Monitor 
Models w/o 
Electrical Control 
Circuit 
Models w/   
Electrical Control 
Circuit 
Note:   
1. Pressure gauge for operating pressure is attached on the MC9 models equipped with 
D04 (Filter-Regulator integrated solenoid valve), and on the MC9 models equipped with 
D14 (Regulator integrated solenoid valve).   
2. Manifold pressure gauge and oil level switch are standard equipped items. 
3.     
・Twin timer or programmable controller should be prepared in advance separately 
for the interval oil shot operation of the pump in the Micron-Lub lubrication unit. 
(MC9 models with electrical control circuit are excepted) 
・User side must make electrical control circuit for the Micron-Lub lubrication system. 
 
4. Filter-Regulator with solenoid valve have no function to remove moisture and gaseous oil 
contained in supply air. (This is 3:-:- of compressed air quality classification). Installations of air 
preparation equipment that satisfy the Micron-Lub lubrication system are required. We Azbil TA 
are dealing in oil removal filters removing gaseous oil, which are recommended to install in air 
supply side, for the compressed air quality classification of 1. - 2.