1ª 10155 ES 9 - 2009
49
MESSAGE EVENTS IN FUNCTION 098
Definition Events in the machine with date and time. With a maximum of 128,
erasing the first after this quantity.
x OEZN: Switch on machine.
x OEZF: Switch off machine.
x ECZC: Reset configuration.
x ECZP: Reset programming of channels, prices, associations, family codes and product
codes.
x ECZM: Reset message programme.
x ECZO: Reset of accounting
x ECZT: Reset of table of functions of the basic menu
Cause: These reset codes happen when they are not written to RAM correctly.
x ECZS: Reset of SDB
x EIR: Communication problem in the MDB payment system
x EAN1: Fault type 1 in change giver. Number of coins is not extracted correctly.
x EAN2: Fault type 2 in change giver. Photocells in the way out of the change giver blocked.
x EAN3: Fault type 3 in a extractor. Three coins were detected in standby mode. The
security relay is activated and it goes out of order.
Cause: Transistor short circuited in the hopper control board.
Exit control activated by transistors or electrostatic discharges.
Short circuit in hopper control board.
x EAN4: Fault type 4 in change giver. Communication problem in the change giver.
x EAN5: Fault type 5 in change giver. Photocell locked permanently during payment
x EAL: Fault validator
x EAM: Fault in the clasificator of coins.
x EAR: Fault in the “V” escrow of three flaps.
x EAB: Fault in the module of refund.
x ELZ2: Fault type 2 in the extraction board modules.
x ELZ3: Fault type 3 in the extraction board modules.