Aesculap
®
Acculan 4
Aesculap Power Systems
Instructions for use/Technical description
Small drill GA344
Gebrauchsanweisung/Technische Beschreibung
Kleine Bohrmaschine GA344
Mode d’emploi/Description technique
Petite perceuse GA344
Instrucciones de manejo/Descripción técnica
Taladro pequeño GA344
Istruzioni per l’uso/Descrizione tecnica
Perforatrice piccola GA344
Instruções de utilização/Descrição técnica
Máquina de furar pequena GA344
Gebruiksaanwijzing/Technische beschrijving
Kleine boormachine GA344
Bruksanvisning/Teknisk beskrivning
Liten borrmaskin GA344
Инструкция по примению/Техническое описание
Малая дрель GA344
Návod k použití/Technický popis
Malá vrtačka GA344
Instrukcja użytkowania/Opis techniczny
Mała wiertarka GA344
Návod na použitie/Technický opis
Malá vŕtačka GA344
Kullanım Kılavuzu/Teknik açiklama
Küçük matkap GA344
사용 설명서 / 기술 설명
소형 드릴 GA344

Table of Contents

Questions and Answers

  • S
    Steven HarperSep 4, 2025
    Why does my B. Braun Aesculap Acculan 4 Drill have insufficient power?
    • A
      andrew77Sep 4, 2025
      If your B. Braun Drill has insufficient power, it could be due to several factors. The product itself might be defective, so follow the operating instructions for preparation and care, and lubricate the product before every sterilization. It may also be necessary to have the manufacturer repair the product. If you are using a serrated tool, make sure the product is operating in right rotation mode. Also, check for a defective attachment, and replace blunt tools.
  • C
    Curtis KirkSep 18, 2025
    What to do if left rotation knob not working on B. Braun Drill?
    • P
      Patricia BeckSep 18, 2025
      To resolve the issue of the left rotation knob not working on your B. Braun Drill, you should have the manufacturer repair the product because the left rotation knob sticks or is defective.
  • A
    ariel91Sep 16, 2025
    What to do if sterile funnel or battery removal device not attachable to B. Braun Aesculap Acculan 4 Drill?
    • G
      gwrightSep 16, 2025
      If the sterile funnel or battery removal device cannot be attached to your B. Braun Drill, ensure you are using a compatible sterile funnel or battery removal device for GA344. If the device is deformed or defective, replace it. If the battery shaft to the product is deformed or defective, have the manufacturer repair the product.
  • D
    Darren RamosSep 14, 2025
    What to do if cap cannot be attached or removed on B. Braun Drill?
    • P
      Patricia WardSep 14, 2025
      To attach or remove the cap on your B. Braun Drill, ensure that you are using the compatible cap for GA344. If the cap is deformed or defective, have the manufacturer repair the cap. If the connection to the product is deformed or defective, have the manufacturer repair the product.
  • D
    Drew GoodSep 12, 2025
    What to do if rinsing adapter cannot be attached to B. Braun Aesculap Acculan 4 Drill?
    • C
      cartermorganSep 13, 2025
      To attach the rinsing adapter to your B. Braun Drill, ensure that you are using the compatible rinsing adapter for GA344. If the connection to the product is deformed or defective, have the manufacturer repair the product. If the thread on the rinsing adapter is deformed or defective, change the rinsing adapter.
  • L
    Lindsey MartinezSep 12, 2025
    What to do if Kirschner wire protection sleeve cannot be attached to B. Braun Drill?
    • J
      Jordan AndersonSep 12, 2025
      To attach the Kirschner wire protection sleeve to your B. Braun Drill, ensure that you are using the compatible Kirschner wire protection sleeve for GA344. If the connection to the product is deformed or defective, have the manufacturer repair the product. If the thread on the Kirschner wire protection sleeve is deformed or defective, change the Kirschner wire protection sleeve.
  • C
    christopher08Sep 9, 2025
    How to fix a B. Braun Drill with a speed control knob that is not working?
    • D
      donaldwilsonSep 9, 2025
      If the speed control knob on your B. Braun Drill is not working, ensure that the product is not in the locked OFF position by turning the safety catch into the ON position. If the knob is still not working, the speed control knob may be sticking or defective, and you should have the manufacturer repair the product.
  • M
    margaretramirezSep 7, 2025
    What to do if the battery cannot be inserted or removed from my B. Braun Aesculap Acculan 4 Drill?
    • D
      Deborah JoyceSep 7, 2025
      If you are unable to attach the battery to your B. Braun Drill, make sure you are using the compatible battery for GA344. If the battery is deformed or defective, have the manufacturer repair it. If the battery shaft to product is deformed or defective, have the manufacturer repair the product.
  • J
    john70Sep 5, 2025
    Why is my B. Braun Drill making a loud running noise?
    • F
      Francisco AtkinsSep 6, 2025
      If your B. Braun Drill is making a loud running noise, this could indicate a problem with the product drive or ball bearings. Follow the operating instructions for preparation and care, and lubricate the product before every sterilization. It may also be necessary to have the manufacturer repair the product. Alternatively, the attachment drive or ball bearings could be defective. In this case, follow the operating instructions for preparation and care, lubricate the attachment before every sterilization, and have the attachment repaired by the manufacturer.
  • D
    David OlsonAug 21, 2025
    What to do if my B. Braun Medical Equipment is not running?
    • A
      April ThomasAug 21, 2025
      If your B. Braun Medical Equipment isn't running, there are several potential causes. First, ensure a battery is inserted. If a battery is present, check if it's charged by charging it in the charger. If the battery seems fine, it could be defective, in which case you should have it repaired by the manufacturer. Also, verify that the product isn't in a secured OFF position; if it is, turn the safety catch to the ON position. Finally, the product itself might be defective and require repair by the manufacturer.

Summary

Applicability

General Information

Intended Use

The hand-held GA344 small drill, combined with the appropriate accessory is used for driving drilling, milling (medullary reaming), sawing and screwing tools.

Task and Function

The product is used in operating rooms in sterile zones outside of the explosion risk zone (such as areas with pure oxygen or anesthesia gases).

Application Environment

The product is used in operating rooms in sterile zones outside of the explosion risk zone (such as areas with pure oxygen or anesthesia gases).

Main Functions and Design Characteristics

Indications

Absolute Contraindications

Relative Contraindications

Safe Handling

Product Description

Scope of Supply

Lists the articles included in the product package, specifying model numbers and designations.

Required Components for Operation

Details the essential components necessary for the product to function, such as batteries and tools.

Operating Principle

Explains how the electric motor is powered by a battery and controlled electronically for various operations.

Preparation

Working with the Device

System Set-up

Connecting Accessories

Provides instructions and safety warnings for connecting various accessories to the product.

Inserting the Rechargeable Battery

Details the procedure for inserting the sterile battery into the product, including safety notes.

Intraoperative Battery Change

Describes the process for safely changing the battery during surgery, emphasizing sterile conditions.

Removing the Rechargeable Battery

Explains how to remove the battery, including safety precautions for hot batteries and avoiding damage.

Protection Against Inadvertent Activation

Attaching and Removing Attachments

Function Checks

Safe Operation

Normal Operation

Describes how to operate the product in right rotation mode, activating the speed control knob.

Tapping or Oscillating Operation

Explains how to activate and deactivate tapping or oscillating modes using specific control knobs.

Validated Reprocessing Procedure

General Safety Notes for Reprocessing

Advises adherence to national regulations, standards, and local hygiene instructions for reprocessing.

General Information for Reprocessing

Preparations at Place of Use

Preparation Before Cleaning

Cleaning and Disinfection

Safety Instructions for Reprocessing

Offers safety instructions regarding cleaning/disinfecting agents, temperatures, and battery protection.

Manual Cleaning with Wipe Disinfection

Automatic Cleaning;Disinfection with Manual Pre-cleaning

Manual Pre-cleaning with a Brush

Describes the manual pre-cleaning steps using rinsing and brushing under running water.

Mechanical Alkaline Cleaning and Thermal Disinfection

Inspection, Maintenance, and Checks

Packaging

Steam Sterilization

Sterilization for the US Market

Storage

Troubleshooting List

Technical Service

Accessories and Spare Parts

Technical Data

Classification According to Directive 93;42;EEC

Specifies the product classification according to the Medical Device Directive 93/42/EEC.

Performance Data and Standards

Provides performance data such as max. power, speed, and dimensions, and relevant standards.

Operating Modes

Details various operating modes like drilling, reaming, and sawing, including application times and pauses.

Environmental Conditions

Specifies the operating and storage/transport conditions for temperature, humidity, and atmospheric pressure.

Disposal

US Distributor and Canadian Contact

B. Braun Aesculap Acculan 4 Specifications