Do you have a question about the B2 HVA Series and is the answer not in the manual?
Defines the scope of the HVA manual and identifies target user groups.
Emphasizes the importance of keeping the manual accessible during HVA operation.
Explains signal words like Danger, Warning, Caution, and Notice for safety.
Details symbols for potential hazards, forbidden practices, and recommended measures.
Details the one-year warranty, its limitations, and liability.
Provides company contact details and copyright restrictions.
Ensures safe operation and adherence to local safety regulations.
Highlights dangers related to exposed connectors and proper earthing.
Restricts test area access and warns about radiation from vacuum bottles.
Covers clean DUT connections, authorized repairs, and product compliance.
Details the types of DUTs and measurements suitable for HVA testing.
Specifies that operators must be qualified electrical technicians.
Lists detailed technical specifications for HVA28TD1 and HVA281 models.
Details technical specifications for HVA34TD-1 and HVA34-1 models.
Details technical specifications for HVA45TD and HVA45 models.
Explains features enhancing safety, testing efficiency, and usability.
Details the external interlock and control system for specific HVA models.
Lists items included with the HVA delivery, noting country-specific items.
Details accessories included in all HVA deliveries and for HVA28.
Lists accessories specific to HVA28TD, HVA34/45, and HVA34TD/45TD models.
Shows front panel diagrams and lists general control/connection components.
Explains the function of each numbered control element on the HVA unit.
Details the elements and functions of the HVA's main menu screen.
Explains how to navigate the HVA display using the navigation knob.
Describes different message types: Information, Question, Warning, and Error.
Explains using the on-screen keyboard for naming and entering data.
Details operations for deleting characters, canceling, or saving changes.
Guides through the initial setup process for the HVA instrument.
Configures date, time, reporting types, and Bluetooth settings.
Selects units and details procedure for USB updates.
Describes how to view system info like software versions and serial numbers.
Instructions for setting the HVA's display language and region.
Covers deleting sequences and importing from USB.
Procedures for deleting and exporting stored test reports.
Describes manual and automatic test modes and their procedures.
Details the various HV testing output modes available on the HVA.
Explains fault management and data transfer options.
Provides safety warnings before starting equipment setup.
Step-by-step guide for connecting cables, power, and initial system boot.
Illustrates connection diagrams for VLF, Sheath, and Vacuum Bottle tests.
Describes how to perform rapid testing using the Manual Test Mode.
Guides through setting up report details for manual tests (RS1-RS14).
Setting basic report fields: Title, Device Under Test, Voltage Rating.
Setting basic report fields: Insulation type and Phase.
Setting extended report fields: Title, Device Under Test, Voltage Rating.
Setting extended report fields: Insulation, Phase, Company Name.
Setting extended report fields: Region, Station, Line Length, DUT Size.
Setting extended report fields: Manufacturer, Work Order, Operator Name, and finishing.
Guides through setting test parameters like waveform, frequency, and duration.
Configures test duration, waveform, frequency, and trip current.
Configures pulse/period and optional test voltage.
Guides on how to initiate and run a test in manual mode.
Steps for starting, activating HV, and test initialization.
Steps for setting voltage, running the test, and ending phases/tests.
Options after test completion: view report or return to main menu.
Overview of configuring, modifying, and saving automatic test sequences.
Accessing sequence editing and entering a title for the test sequence.
Setting sequence parameters: Work Order, Device Under Test, Insulation.
Setting sequence parameters: Voltage Rating, Test Type, Test Standard.
Setting sequence parameters: Test Purpose, U0, and proceeding.
Setting actions for arc management, overload, and voltage not reached.
Setting minimum insulation resistance actions and storing the sequence.
Accessing sequence editing and entering a title for the test sequence.
Setting sequence parameters: Work Order, Arc Management, Overload.
Setting actions for voltage not reached, insulation, and period count.
Setting sequence parameters: Voltage Steps, Test Voltage, Duration.
Setting sequence parameters: Waveform, Frequency, and storing.
Overview of running automatic tests using last used or different sequences.
Steps for starting, choosing, and selecting an automatic test sequence.
Steps for reporting settings and reviewing the sequence summary.
Steps for HV activation, test startup, and running the test.
Options after automatic test completion: new phase, new test, report, or main menu.
Describes methods to interrupt a test: Routine STOP, Alternative, and Emergency Stop.
Flowchart illustrating discharge status and procedures based on conditions.
Details the application of HVA Tan Delta testing for insulation diagnostics.
Illustrates connection diagrams for VLF withstand tests with Tan Delta.
Step-by-step guide for connecting equipment for Tan Delta testing.
Illustrates connection diagrams for VLF tests with Tan Delta and guard.
Step-by-step guide for Tan Delta test setup, including guard connection.
Details using corona shields for Tan Delta diagnostics on the near end.
Details using corona shields and guards on the far end for short cables.
Guides on how to run a test in manual mode with Tan Delta.
Steps for starting, activating HV, and setting voltage for Tan Delta test.
Options after Tan Delta test completion: next phase, new test, report.
Option to return to the main menu after completing the Tan Delta test.
Introduction to software tools for HVA analysis and reporting.
Details available report types (Basic, Extended) and activation settings.
Guides on entering user-selected names for reports and sequences.
Details operations for deleting entries, canceling, or saving names.
Opening the reports section and viewing the list of stored reports.
Managing reports by viewing content, graph data, or editing.
Continuing reports, deleting them, or returning to the main menu.
Illustrates disconnection diagrams for HVA units under normal conditions.
Step-by-step instructions for normal disconnection of the HVA system.
Illustrates disconnection diagrams for system failures with HVA units.
Step-by-step instructions for disconnecting the HVA in case of system failure.
Safety warnings and instructions for cleaning HVA cables and connection points.
Guidelines for authorized personnel performing maintenance and repairs.
Lists optional accessories available for order and their descriptions.
Defines terms and abbreviations from Arc to HV used in the manual.
Defines terms and abbreviations from MWT to VLF used in the manual.
Declaration of conformity for HVA models meeting European Council requirements.
Declaration of conformity for HVA34-1 / TD, listing European Council regulations.
Declaration of conformity for HVA45 / TD, listing European Council regulations.