RIGGING & ASSEMBLY INSTRUCTIONS
Series 3000 Cooling Tower
Series 3000
Question and Answer IconNeed help?

Do you have a question about the BAC 3000 Series and is the answer not in the manual?

BAC 3000 Series Specifications

General IconGeneral
Series3000 Series
CategoryDesktop
GraphicsIntegrated Intel UHD Graphics
Operating SystemWindows 10 Pro
PortsUSB 3.0, HDMI, DisplayPort, Ethernet, Audio

Summary

Introduction

Safety

Adequate precautions for installation and location to safeguard equipment, premises, and public.

Shipping

Details on how BAC Cooling Towers are factory assembled for uniform quality and minimum field assembly.

Pre-Rigging Checks

Procedure to thoroughly check delivered unit for required items and shipping damage before signing bill of lading.

Unit Weights

Verification of section weights from certified drawings for rigging purposes.

Anchoring

Details on bolting the unit to support beams and considerations for proper operation and ratings.

Cold Weather Operation

Methods to protect products from damage and reduced effectiveness due to freeze-up.

Location

Guidelines for positioning units to ensure adequate fresh air supply and prevent discharge air recirculation.

Warranties

Reference to the Limitation of Warranties applicable at the time of sale/purchase.

Unit Operation

Guidance to refer to the Operation & Maintenance Manual prior to start-up.

Unit Rigging & Assembly

Rigging

General instructions for lifting and handling units using spreader bars and safety slings.

Single-Cell Installation

Procedures for assembling single-cell cooling tower units, including two-piece section assembly.

Multi-Cell Installation

Procedures for assembling multi-cell cooling tower units, including flume box installation.

Flume Box Installation

Step-by-step guide for installing flume boxes to equalize water level in multi-cell basins.

Positive Closure Plate Installation

Instructions for installing optional closure plates to isolate individual cells for maintenance.

Fan Guard Installation

Instructions for installing fan guards, emphasizing safety precautions during operation.

Top Inlet Piping Installation

Guidance for installing top inlet piping, including dimensions and support considerations.

Motor Location and Conduit Installation

Details on electrical conduit routing and motor placement for various fan systems.

Optional Accessory Installation

ENDURADRIVE™ Fan System Installation

Installation instructions and warnings for the ENDURADRIVE™ Fan System with VFD.

Whisper Quiet Fan Installation

Steps for installing the optional Whisper Quiet Fan, including handling and torque specifications.

Side Outlet Depressed Sump Box Installation

Installation of the optional side outlet depressed sump box for water outlet connections.

Factory Pre-Wired Terminal Box Installation

Installation of the optional factory pre-wired terminal box for fan motor and switch wiring.

Additional Optional Accessories and Equipment

Guidance on installing pre-assembled optional accessories based on customer information packet.