Pulsar 150/180 DTS-i
Service Station Manual
64
Dealer Development Center
Akurdi Pune
IMPORTANCE OF PM SCHEDULE EXECUTION
6. Each cell should have specific gravity of 1.240.
7. Add distilled water & maintain level in between Min & Max level.
Required Special Tools & Equipment
Hand Gloves Distilled Water Bottle
with Dropper
Hydrometer
8. Use Nitrile rubber hand gloves while topping up battery electrolyte level &
checking of specific gravity.
Note :
- Dry battery (PDI) - Initial filling by electrolyte with charging for 10 ~ 12
hours.
- Wet battery (PDI / Servicing) - Add only distilled water & maintain level.