2 english
BTL  PF _ 400- _ _ _ _ -C15A _ _ _ _ -000S35
Magnetostrictive Linear Position Sensor – Profile Style
Installation
NOTICE
Improper installation
Improper installation can compromise the function of the 
BTL and result in damage.
 ► Ensure that no strong electrical or magnetic fields 
are present in the direct vicinity of the BTL.
 ► Be sure to maintain the specified distances and 
separations.
Dimensions see image.
Captive magnets
BTL5-F-2814-1S BTL5-F-2814-1S
 1 
 44 
 50.4 
 1 
 31.5 
 36.5 
Note when installing the magnet:
–  Avoid lateral forces.
 – Connect the magnet to the machine member with a 
joint rod (see Accessories).
Floating magnets
BTL5-P-3800-2 BTL5-P-5500-2
 1 
 34+4 
 39+4 
 C 
 1 
 45+10 
 50+10 
 C 
BTL6-A-3800-2 BTL6-A-3801-2
 1 
 53+4 
 58+4 
 C 
 1 
 42+4 
 47+4 
 C 
Installation (continued)
Observe the following when installing the magnet:
–  To ensure the accuracy of the magnetostrictive linear 
position sensor, fasten the magnet to the moving 
member of the machine only using non-magnetizable 
screws (stainless steel, brass, aluminum).
–  The moving member must guide the magnet on a 
parallel line to the BTL.
–  The distanceA between the magnet and parts made of 
magnetizable material must be at least 10mm.
 A   A 
–  For distance B between the magnet and the BTL and 
for the center offset C (see image) the following values 
must be maintained:
Magnet type Distance B
1)
Offset C
BTL5-P-3800-2 0.1…4mm ±2mm
BTL5-P-5500-2 5…15mm ±15mm
BTL6-A-3800-2 4…8mm
2)
±5mm
BTL6-A-3801-2 4…8mm
2)
±5mm
1)
 The selected distance must remain constant over the entire measuring 
length.
2)
 For optimal measurement results: 6…8mm
–  When using multiple magnets a minimum separation of 
65 mm must be maintained between them.
Any orientation is permitted. Mount the BTL on a level 
surface of the machine using the provided mounting 
clamps and cylinder-head screws.
In order to avoid resonant frequencies caused by 
vibrations, we recommend positioning the 
mounting clamps at irregular intervals.