1686-001 en/2022-05
Operating Manual
SONOREX DIGITEC
SONOREX DIGITEC-RC
High-performance ultrasonic baths
Applies to:
DT 31, DT 31 H, DT 52, DT 52 H
DT 100, DT 100 H, DT 102 H, DT 102 H-RC, DT 103 H, DT 106
DT 156, DT 156 BH
DT 255, DT 255 H, DT 255 H-RC
DT 510, DT 510 H, DT 510 H-RC, DT 512 H
DT 514, DT 514 H, DT 514 BH, DT 514 BH-RC
DT 1028, DT 1028 H, DT 1028 CH
DT 1050 CH
Dokument: 1686-001Sprache: enVersion: 2022-05

Other manuals for BANDELIN SONOREX DIGITEC

Questions and Answers

Summary

Understanding the Operating Manual

Safety Guidelines and Precautions

Safe Use of the Ultrasound Bath

Details general applications and safe usage practices for the ultrasound bath, including its intended purpose and basic operation.

Medical Sector Use and Contraindications

Covers the specific medical application, user qualifications, prohibited items, and potential side effects of the ultrasound bath.

Preventing Cross-Contamination and Infection

Provides essential steps to prevent cross-contamination and infections, especially critical when used in medical environments.

Child Safety and Electric Shock Hazards

Highlights the importance of child safety and outlines crucial precautions to prevent hazardous electric shocks from the device.

Health Risks from Ultrasound Noise

Explains the potential health impacts of prolonged exposure to ultrasound noise and recommends protective measures like hearing protection.

Hazards from High Temperatures and Ultrasound

Warns about risks associated with high temperatures and direct ultrasound exposure, including burns and tissue damage.

Preparation Safety and Fluid Disposal

Covers safety precautions for chemical preparations and proper disposal procedures for sonication fluids, including environmental considerations.

Tank Erosion and Bath Damage Prevention

Details tank erosion causes, consequences, and preventative measures to extend the lifespan and integrity of the oscillating tank.

Wireless Interference and Safety Labels

Discusses potential interference with wireless devices and the importance of maintaining legible safety stickers on the unit for user awareness.

Design and Functional Overview

Device Structure and Components

Presents a visual overview and labeling of the main physical components and parts of the ultrasound bath device.

Control Panel and Operation Modes

Explains the control panel layout, button functions, and different operation modes for both heated and non-heated models.

Ultrasound Functionality and SweepTec

Details the core ultrasonic cavitation principle and the role of SweepTec® technology for achieving homogeneous cleaning results.

Remote Control and PC Integration

Describes the infrared interface for remote PC control, the necessary software, and how to obtain the command set.

Preparing the Ultrasound Bath for Use

Installation Site Requirements

Outlines essential conditions for the installation location, including surface stability, ventilation, and nearby water access.

Fitting the Ball Valve

Provides step-by-step instructions for attaching the supplied ball valve, hose grommet, and hose to specific models.

Performing Pre-Operation Tests

Guides users through a function test to verify the device's readiness, including audible checks and the foil test recommendation.

Initial Tank Rinsing and Cleaning

Details the necessary procedure for rinsing the oscillating tank before initial use and removing protective preservatives.

Operating the Ultrasound Bath

Direct and Indirect Sonication Methods

Explains the two primary methods for sonication and their specific applications, including the use of appropriate accessories.

Sonication Fluid Selection and Dosing

Discusses appropriate sonication fluids, recommended cleaning agents, and how to calculate correct concentrations for optimal cleaning.

Determining Optimal Sonication Time

Guides on selecting the appropriate sonication time based on factors like agent, temperature, and soiling to avoid damage and ensure effectiveness.

Safe Filling of the Oscillating Tank

Provides instructions and cautions for filling the tank with water and agents, addressing risks of scalding, condensation, and powder mixing.

Starting, Stopping, and Continuous Sonication

Details the step-by-step process for activating, deactivating, and managing continuous operation of the sonication function.

Operating the Heating Function

Explains how to switch the heating on and off for specific models and set the desired working temperature within the specified range.

Preventing Retardation of Boiling

Describes the automatic function designed to prevent boiling retardation at high temperatures and how to configure its continuous activation.

Degassing Sonication Fluid (DEGAS)

Explains the necessity of degassing sonication fluids for increased effect and demonstrates how to use the DEGAS function for rapid degassing.

Loading Items for Treatment

Provides crucial guidelines on properly placing items in the bath for optimal cleaning, including distribution, submersion, and air bubble removal.

Safe Removal of Treated Objects

Details safe procedures for removing hot objects and accessories from the bath, emphasizing cooling, handling precautions, and rinsing.

Emptying the Oscillating Tank Safely

Guides on safely emptying the tank, addressing risks of electric shock and burns, and outlines the cleaning process for the tank.

Enabling and Blocking Continuous Operation

Explains the procedure to enable or block the continuous operation mode, preventing accidental activation and ensuring controlled usage.

Troubleshooting Malfunctions and Errors

Lists common errors like insufficient effect or uneven noises, their potential causes, and recommended troubleshooting steps for resolution.

Maintenance and Care Procedures

Cleaning and Maintaining the Ultrasound Bath

Provides instructions for cleaning the housing and caring for the oscillating tank to ensure longevity, performance, and prevent corrosion.

Performing Device Tests and Checks

Details checks for indicator lamps, ultrasound/heating output verification, and ultrasonic effect testing, including recommended intervals.

Conducting the Foil Test

Explains the purpose and procedure of the foil test for verifying cavitation intensity and distribution, including critical test conditions.

Repair and Decontamination Procedures

Outlines the process for sending the unit for repair, including necessary decontamination steps, forms, and contact information.

Proper Disposal of the Ultrasound Bath

Device Specifications and Information

Technical Data Overview

Lists electrical specifications, operating parameters, protection classes, and ultrasonic frequency for various models.

Ambient Conditions for Operation

Specifies permissible operating conditions including temperature, humidity, altitude, and overvoltage category for safe and effective use.

CE Conformity and Compliance

Confirms the ultrasound bath's compliance with EU medical device and directive standards, ensuring safety and quality.

Sonication Fluid Dosing Guidelines

Available Accessories for Ultrasound Baths

Accessory Descriptions and Uses

Provides detailed descriptions for various accessories like baskets, lids, holders, and trays designed to enhance bath functionality.

Accessory Compatibility by Model

Details which specific accessories are compatible with particular ultrasound bath models, presented in a clear tabular format.

Further Accessory Options and Types

Lists additional accessory options such as beaker holders, test tube racks, and fixation clamps, along with their specific applications.

Accessory Model Cross-Reference Guide

Offers a comprehensive table mapping various accessories to specific ultrasound bath types for efficient selection and compatibility checks.

Specialized Accessory Mounts and Holders

Describes specialized items like mounting brackets, handle adapters, and sieve holders for specific laboratory and cleaning tasks.

Accessory Integration and Application Guide

Provides guidance on integrating specialized accessories like mounting brackets, test tube holders, and fixation clamps with different bath models.

BANDELIN SONOREX DIGITEC Specifications

General IconGeneral
BrandBANDELIN
ModelSONOREX DIGITEC
CategoryLaboratory Equipment
LanguageEnglish

Related product manuals