Commissioning • Connection examples
Chapter 3
Commissioning
201Automation PC 810 with GM45 CPU board User's Manual V 1.14
4.11 Six AP900 and two AP800 devices via SDL (onboard) and SDL (AP Link)
Three Automation Panel 900 (max. UXGA) units and one Automation Panel 800 are connected
to the integrated SDL interface (onboard) via SDL. Additionally, three Automation Panel 900
(max. UXGA) units and one Automation Panel 800 are operated on the optional SDL
transmitters. The Automation Panels in each line must be the same type. The two lines show
different content (Extended Desktop), but displays in the same line show the same content
(Display Clone).
USB is supported up to a maximum distance (segment 1 + segment 2) of 30 m on the first two
displays. Starting at a distance of 30 m, USB is only available on the first display (front and back)
up to a maximum of 40 m. USB devices can only be connected directly to Automation Panel 900
devices (without a hub).
Figure 100: Configuration - Six AP900 and two AP800 devices via SDL (onboard) and SDL (AP Link)
Automation Panel 800
11
2
USB not
possible
Automation Panel 800
3
10
8
9
USB not
possible
Link: 5DLSDL.1000-01
Link: 5DLSDL.1000-01
USB
possible
USB OK
Link: 5DLSDL.1000-01
Monitor / panel
connection
AP Link
connection
Link: 5DLSDL.1000-01
USB not
possible
x
Internal APC
panel number
1
Link: 5DLSDL.1000-01
USB
possible
SDL Segment 1
max.40 Meter
Link: 5DLSDL.1000-01
0
SDVO-C
SDVO-B
USB OK
SDL Segment 2
max.40 meters
Automation PC 810
with AP Link
5AC600.SDL0-00
SDL Segemt1
max.40 meters
SDL Segment 3
max.40 meters
SDL Segment 4
max.40 meters
SDL Segment 2
max.40 meters
SDL Segment 3
max.40 meters
SDL Segment 4
max.40 meters
46
5
12
13
Independent of segment length
Depends on segment length
Not supported