EasyManua.ls Logo

Banner Q5XKLAF2000-Q8 - IO-Link Interface

Banner Q5XKLAF2000-Q8
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4 IO-Link Interface
IO-Link is a point-to-point communication link between a master device and sensor. Use IO-Link to parameterize sensors
and transmit process data automatically.
For the latest IO-Link protocol and
specifications, see
www.io-link.com
.
Each IO-Link device has an IODD (IO Device Description) file that contains information about the manufacturer, article
number, functionality etc. This information can be easily read and processed by the user. Each device can be
unambiguously
identified via the IODD as well as via an internal device ID. Download the Q5X's IO-Link IODD package (p/n
206833) from Banner Engineering's website at
www.bannerengineering.com
.
Banner has also developed Add On Instruction (AOI) files to simplify ease-of-use between the Q5X, multiple third-party
vendors' IO-Link masters, and the Logix Designer software package for Rockwell Automation PLCs. Three types of AOI files
for Rockwell Allen-Bradley PLCs are listed below. These files and more information can be found at
www.bannerengineering.com
.
Process Data AOIs—These
files can be used alone, without the need for any other IOLink AOIs. The job of a Process Data
AOI is to intelligently parse out the Process Data word(s) in separate pieces of information. All that is required to make use
of this AOI is an EtherNet/IP connection to the IOLink Master and knowledge of where the Process Data registers are
located for each port.
Parameter Data AOIs—These
files require the use of an associated IOLink Master AOI. The job of a Parameter Data AOI,
when working in conjunction with the IOLink Master AOI, is to provide quasirealtime read/write access to all IOLink
parameter data in the sensor. Each Parameter Data AOI is
specific to a given sensor or device.
IOLink Master AOIs—These files require the use of one or more associated Parameter Data AOIs. The job of an IOLink
Master AOI is to translate the desired IOLink read/write requests, made by the Parameter Data AOI, into the format a
specific IOLink Master requires. Each IOLink Master AOI is customized for a given brand of IOLink Master.
Add and configure the relevant Banner IOLink Master AOI in your ladder logic program first; then add and configure Banner
IOLink Device AOIs as desired, linking them to the Master AOI as shown in the relevant AOI documentation.
Q5X Laser Triangulation Sensor with Background Suppression
www.bannerengineering.com - Tel: +1.763.544.3164 29

Table of Contents