Required Overcurrent Protection
WARNING: Electrical connections must be
made by qualified personnel in accordance
with local and national electrical codes and
regulations.
Overcurrent protection is required to be provided by end product
application per the supplied table.
Overcurrent protection may be provided with external fusing or via
Current Limiting, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go to
www.bannerengineering.com
.
Supply Wiring (AWG) Required Overcurrent Protection (Amps)
20 5.0
22 3.0
24 2.0
26 1.0
28 0.8
30 0.5
Shock
MIL-STD-202G, Method 213B, Condition I (100G 6x along X, Y and Z
axes, 18 shocks), with sensor operating
Operating Conditions
–10 °C to +50 °C (+14 °F to +122 °F)
35% to 95% relative humidity
Storage Temperature
–25 °C to +70 °C (–13 °F to +158 °F)
Certifications
Industrial
Control
Equipment
3TJJ
Class 2 power
UL Environmental Rating: Type 1
Excess Gain
Excess Gain Using a 90% White Card
2
Response Speed (ms) at 100 mm at 500 mm at 1000 mm at 2000 mm
3 150 50 15 4
5 150 50 15 4
15 725 (225) 250 (75) 70 (25) 15 (6)
25 1250 (800) 450 (250) 125 (70) 30 (15)
50 2500 (1250) 900 (450) 250 (125) 60 (30)
2
Standard excess gain available in 15, 25, and 50 ms response speeds; standard excess gain provides increase noise immunity.
Q5X Laser Triangulation Sensor with Background Suppression