19
ECO 40 / 52 / 55
3.4. FITTING THE STOVE
3.4.1. Connecting the smoke outlet
The appliance can make use of either a top or rear connection Ø150 mm
(Ø148 mm external) for the • ue (chimney).
Smoke outlet top-connection
Factory assembled, the appliance is provided with a (detachable) smoke
outlet top-connection. This connection is intended for steel stovepipes, double/
single-skinned stainless steel (insulated) • ues or double/single-skinned • exible
stainless steel • ues.
Smoke outlet rear-connection
In order to be able to assemble the smoke outlet rear-connection, remove the
• ue gas • ap and the brake plate • rst.
See chapter 11 for the disassembly sequence: “Sequence for replacing the
interior of the appliance”.
Fit the sealing plate and the protective plate to the other opening.
Situate the appliance in such a way that the • ue gas outlet is precisely in line
under the chimney connection (niche pipe) in the ceiling (top connection) or with
the chimney connection (niche pipe) in the wall (rear connection).