ECO 40 / 52 / 55
6. USE
6.1. VENTILATION
Air is a vital component of the combustion process. Ensure that there is a
suf• cient supply of fresh air. For each kilo of wood that you put on the • re (door
closed), 10 - 15 m
3
of extra air is needed. That means 50 m
3
per hour! As you
can see, a plentiful supply of air is essential. Fresh air supply opening: minimal
50
cm
2
(= Ø80 mm).
6.2. GETTING THE FIRE GOING (Figure 1)
When you start the • re, the chimney is still cold and there is little draught. This
means that the chimney’s capacity to draw in air is limited. That is why the air
supply has to be assisted by opening the locking slider (and/or the door) and air
supply slider. Use dry, • ne wood and some scrunched-up paper or • relighters to
start the • re.
open close
Locking slider for operating pin of " ue gas " ap (inside of door).
Locking slider all the way to the right (closed):
Flue gas " ap operation works normally:
Door open Pin comes forwards Flue gas " ap open
Door closed Pin is pressed in by the door Flue gas " ap closed
Locking slider all the way to the left (open):
Flue gas " ap always remains fully open !!