EasyManua.ls Logo

Base aire AirWerx 120X - User Manual

Base aire AirWerx 120X
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Tel: 1-888-641-8862
Web: www.baseaire.com
E-mail: sales@baseaire.com
Installation & Operations Manual
AirWerx 120X
Patent pending
Specifications subject to change without notice.

Questions and Answers

  • M
    Matthew DuncanAug 2, 2025
    What to do if my Base aire AirWerx 120X Dehumidifier display is blank?
    • C
      Christopher TaylorAug 3, 2025
      If the display is blank, first check the power cord to ensure both ends are properly plugged in. If the issue persists, reset the power, as there may have been a power outage.
  • D
    djonesAug 7, 2025
    What to do if my Base aire AirWerx 120X shows the E4 trouble code?
    • L
      lauriedouglasAug 7, 2025
      If your dehumidifier displays the E4 trouble code, it indicates a problem with the pump. Verify that the pump is correctly installed and functioning. If it is, unplug the unit for two minutes, and then restart it.
  • C
    Christopher DominguezAug 12, 2025
    What to do if my Base aire AirWerx 120X has no airflow?
    • B
      Brian BakerAug 12, 2025
      If there is no airflow, the filter may be dirty, so try cleaning it. Also, check the air inlet and outlet to ensure they are not blocked. Clear any blockage if present.
  • S
    Shawna CruzAug 17, 2025
    What does the LO error code mean on my Base aire AirWerx 120X Dehumidifier?
    • J
      John McfarlandAug 17, 2025
      The LO error code indicates that the room temperature is below 33 degrees. Increase the room temperature so that it is within the operating range (above 33 degrees). If the error still displays, check the sensor.
  • T
    tcaldwellAug 22, 2025
    What does the HI error code mean on my Base aire Dehumidifier?
    • T
      Tom JordanAug 22, 2025
      The HI error code means that the room temperature is above 105 degrees. To resolve this, decrease the room temperature so it is within the operating range (below 105 degrees). If the error persists, check the sensor.
  • M
    Melanie BondAug 28, 2025
    What does the E1 trouble code mean on a Base aire Dehumidifier?
    • C
      Corey JacksonAug 28, 2025
      The E1 trouble code indicates a humidity sensor or communication error. Check to ensure that the sensor wire is connected at both ends. If no issues are visible, the sensor may be faulty.

Summary

Specifications

Installation Requirements

Installation

Unit Placement

Instructions for proper placement of the dehumidifier unit on a level surface.

Drain Line Setup

Steps to connect the drain line hose to the unit and ensure a secure fit.

Electrical Connection

Final connection step for the dehumidifier to a suitable electrical outlet.

Key Functions

Power Key

Explanation of the power button functions for turning the unit on and off.

Arrow Buttons

Details on using up/down arrows to set the desired humidity setpoint.

Indicator Lights

Remote Control Instructions

Operating Instructions

Start the machine

Steps to turn on the dehumidifier using the power key.

Adjust the settings

How to use the arrow keys to set the desired humidity level.

Stop the machine

Procedure for turning off the dehumidifier, noting the fan delay.

Water Drainage

Details on automatic and manual water drainage operations via the condensate pump.

Unit Diagram

Maintenance

Troubleshooting

Spare Parts

Limited Warranty

Base aire AirWerx 120X Specifications

General IconGeneral
ModelAirWerx 120X
CategoryDehumidifier
Power Supply115V/60Hz
RefrigerantR410A
Water Removal (Pints/Day)120
Water Tank CapacityNo Tank (Designed for continuous drainage)
Noise Level58 dB(A)
Operating Temperature33°F - 105°F