EasyManua.ls Logo

Bauer Compressors P1 - 4.5 PURIFICATION CARTRIDGE APPLICABILITY

Default Icon
104 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Purification Systems
Page 29 3rd Edition, Rev 0 Chg 6
4.5 Purification Cartridge Applicability
4.5.1 Purification Chamber Position References
The key to determining the reference location of the chamber and it corresponding cartridge is shown in
Figure 4-7. The location begins with A closest to the System Output and works back toward the Com-
pressor Input the with as many letters as required. The Oil and Water Separator is not designated but is
always closest to the Input. In Table 4-1 through Table 4-4 the Cartridge Part Numbers are cross-indexed
to the Purification System Model Number and the highlighted Chamber Part Number. The Cartridge Part
Numbers are used with Figure 4-24 through Figure 4-30 for determining the correct part numbers for
maintenance and repair.
Figure 4-7 Purification Chamber Position
Table 4-1: Cartridge Applications for Purification Systems: P1 to P4
P/N Description
P1
P2
P2S
IP2S
P4
080143 10” Chamber A A
080144 27" Chamber A B
080145 27" Securus Chamber A A
058821A 10” Purification Cartridge, Breathing A A
058825A 27" Dryer Cartridge B
058827A 27” Purification Cartridge, Breathing A
060037A 27” Securus Cartridge, Breathing A A
OUT
Reference Positions
A
B
C
IN

Table of Contents