Page 11For technical questions, please call 1-888-866-5797.Item 70138
SAFETYOPERATIONMAINTENANCE SETUP
General Operating Instructions
TO PREVENT ELECTRIC SHOCK AND DEATH: Test Ground Fault Circuit
Interrupter (GFCI) before each use. The GFCI does not protect against electrical
shock due to contact with both circuit conductors or a fault in any wiring supplying in this device. Do not
alter or disable the GFCI. Do not use an extension cord.
This unit is intended for light to moderate cleaning. It is not intended for paint stripping or deep concrete cleaning.
1. Uncoil High-Pressure Hose completely. Do not use
Pressure Washer if Hose is kinked or looped.
2. The Spray Gun includes a Trigger
Safety Lock that locks the Trigger.
• Push Trigger Safety Lock in from
the left side to lock the Trigger.
• Push Trigger Safety Lock in from
the right side to unlock Trigger.
Trigger
Safety
Lock
3. Point Spray Gun in safe direction, press Trigger
to release all pressure, then release Trigger.
4. Plug GFCI into dedicated, grounded
120V outlet, then press the RESET
button to ensure proper operation.
Reset
Test
5. Turn on water supply.
6. Turn Power Switch to ON position.
Note: If the unit does not turn on or turns
off suddenly, turn Power Switch to OFF
position, then check and reset the GFCI.
NOTICE: Pressure Washer will run only while
Trigger is pressed. When trigger is released,
Pump will turn off. Do not leave idle for more
than one minute without spraying.
7. Test spray an inconspicuous area:
a. Set Nozzle to low-impact fan spray.
b. Point Spray Gun at 45° angle to test area.
Unlock Trigger Safety Lock, then press
Trigger. Be aware of kick back.
c. Spray test area, adjusting pressure,
as needed, by changing distance from
surface and/or adjusting Nozzle.
d. If using detergent:
• Turn off unit, fill Detergent Tank,
then attach Black Nozzle.
• Turn on unit, then spray area with detergent
according to detergent manufacturer's
instructions. Scrub surface as necessary.
• Turn off unit, then switch to another Nozzle.
• Turn on unit, then spray area to rinse off
detergent, adjusting pressure as needed
by changing distance from surface and/
or changing to a different Nozzle.
e. Inspect test area for damage or discoloration.