Operating Manual for FAN Press Screw Separator PSS 1.1-300 
 
No solids are produced 
 
No liquid is discharged 
 
Separator is running  
 
  
1.  The  material  supply  has  been  in-
terrupted: 
  The pump is off 
  Inflow element or ventilation open-
ing  blocked;  a  siphon  effect  oc-
curs  [“overflow  line  is  completely 
filled”];  the  outlet  of  the  overflow 
line is submersed in the liquid. 
  Clogged / restricted effluent line  
2.  The auger is turning clockwise. 
 
3.  The rotation direction of the pump 
is  incorrect,  the  supply  line  is  vi-
brating 
4.  Long  fibers  (  hey,stray,  etc.)  are 
blocking the liquid transport 
1.  Check: Switch cabinet and overflow 
line. 
  Inspect and start the pump. 
  Clean the lines. Install a ventilation 
pipe with a larger cross-section; re-
duce  the  pump  capacity;  ensure 
that the overflow line is clear. 
  Ensure  that  the  liquid  can  drain 
freely. 
2.  Swap  the  two  phases  of  the  elec-
tricity  line  so  that  the  auger  turns 
counterclockwise. 
3.  Change the rotation direction of the 
pump. 
 
4.  Replace  the  cutting  blade  in  the 
pump cutting unit. 
 
Solid discharge too low 
Effluent discharge too low 
(lower than is typical for this 
medium) 
 
Separator is running 
 
 
 
 
 
 
1.  Pump  capacity  (feed  rate)  is  too 
low  –  no  overflow  in  the  bypass 
line 
 
2.  Lifting  effect  in  the  overflow  line, 
the medium is being drawn out of 
the separator 
 
 
3.  Too much contact pressure 
 
4.  Excess wear on the screen or au-
ger 
 
 
5.  Screen  positioned  incorrectly  or 
clogged; 
 
 
6.  Auger channels clogged 
 
 
 
 
7.  Screen only worn in certain places, 
guide  rails  for  the  screen  not  set 
correctly 
8.  Slurry is pumped / stirred too much 
(ground fine) 
1.  Inspect  pump  (rotation  direction) 
and/or control the pump capacity.  
Check the transport line. 
 
2.  Affix  the  ventilation  valve  /  pipe  to 
the inflow of the separator.  
Reduce  the  feed  rate  so  that  the 
overflow  pipe  is  no  more  than  half 
full.  Ensure  that  the  overflow  can 
flow out freely. 
 
3.  Reduce the leverage of the weights. 
4.  Check  the  auger  diameter,  check 
the  screen  for  wear.  Replace  the 
screen and auger, if necessary. 
5.  remove the screen for cleaning 
6.  Clean  the  auger,  contact  the  FAN 
company  concerning  possible 
changes to the inflow of the separa-
tor. 
7.  Check  the  guide  rails  for  soiling  / 
clogging. 
8.  Install  a  buffer  container  at  the 
inflow. 
 
Solid discharge is very low 
Effluent discharge is normal 
 
Separator is running 
 
1.  The solid portion in the inflow is 
very low 
2.  The gap width of the screen is too 
large 
1.  Add some solid to the inflow. 
2.  Install a screen with a smaller gap 
width. The available screen gap 
widths are:  0.25, 0.50, 0.75, and 
1.0 mm. After changing the gap 
width, accustom yourself to a 
change in the “normal” operating 
condition.