Baumatic BC190.2TCSS - Minimum Flow Adjustment for the Oven and Grill Burners

Baumatic BC190.2TCSS
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
35
o Loosen the burner screw (V) and then carefully pull the burner
away from its support. IMPORTANT: Care must be taken to
ensure that no damage is caused to the ignition plug or
the thermocouple.
o Unscrew the injector using a 10 mm spanner and replace it with
the stipulated injector for the new gas supply (see table below).
Gas
consumption
Power
(kW)
Burner Types
of gas
Pressure
(mbar)
Injector
Marking
(1/100
mm)
g/h l/h Max. Min.
Natural
(G20)
20
150 - 429
Butane
(G30)
28 95-X 218 -
Oven
Propane
(G31)
37 95-X 214 -
4.50 2.00
Natural
(G20)
20 115 - 191
Butane
(G30)
28 68 145 -
Grill
Propane
(G31)
37 68 143 -
2.00 N/A
IMPORTANT: You must change the oven and grill injectors.
IMPORTANT: After changing the injectors YOU MUST follow the
minimum flow adjustment section below.
Minimum flow adjustment for the oven and grill burners
All work must be carried out by a GASSAFE
registered engineer.
o Light the burner and set the knob at the minimum position.
o Remove the knob from the
tap and place a small bladed
screwdriver in the screw
indicated in the picture
opposite.
o Unscrew the adjusting screw,
in order to increase the gas
flow or tighten the adjusting
screw to decrease the gas
flow.