Installation
Mono Power Unit BUM 62, 63, 64 45
Baumüller Nürnberg GmbH 5.94005.12
y ZK+, ZK-
DC link of further units if the total power of the input rectifier is not exceeded.
(max. 36 kW, see Technical Data, input rectifier).
If UL508C has to be observed: Nominal tightening torque of the terminal screws: 4 Nm resp. 35,4
pound-inches.
y 1C1, 1D1
DC link of further units e.g. ballast.
If UL508C has to be observed: Use 60°C / 75° C copper conductors only (UL508C, Nov 27, 1996,
Tab. 39.2). Nominal tightening torque of the terminal screws: 6 Nm resp. 53,1 pound-inches.
BUM 63: M 8 terminals
BUM 64: M 10 terminals