High Efficiency Wall Hung Condensing Gas Boiler
Baxi Combi
224 – 228 – 424 – 428

Table of Contents

Other manuals for Baxi COMBI 228

Questions and Answers

  • A
    Anthony WatkinsSep 18, 2025
    What does 'Incorrect configuration settings C1/C2' mean on my Baxi COMBI 228 Boiler?
    • N
      Nicholas NicholsSep 19, 2025
      If your Baxi Boiler displays 'Incorrect configuration settings C1/C2', it means there is incorrect C1/C2, so reset C1/C2.
  • M
    Mark OrtegaAug 25, 2025
    What to do if my Baxi COMBI 228 has low system water pressure?
    • C
      Christopher PrestonAug 25, 2025
      If your Baxi Boiler shows low system water pressure, it could be due to a water leak. Check the boiler and the entire system for any signs of leakage. You may also need to repressurize the system.
  • K
    Kenneth MillerAug 25, 2025
    How to fix no domestic hot water in my Baxi COMBI 228 Boiler?
    • C
      Christopher RossAug 26, 2025
      If your Baxi Boiler isn't providing domestic hot water, start by ensuring the boiler is receiving power by checking the fuses and switches. Also, verify that the gas isolation cock is fully open and, if applicable, that your prepayment meter has sufficient credit. It's also possible that the DHW function is switched off, so try activating the DHW mode. Check the water pressure; if it's below 0.5 bar, re-pressurise the system. Finally, make sure the flow is at least 2.5 litres per minute.
  • M
    Michael MartinezAug 27, 2025
    Why are my radiators cold with my Baxi Boiler?
    • E
      Emily HoodAug 27, 2025
      If your radiators are cold when using your Baxi Boiler, first, check the temperature set point for the heating and increase it using the CH temperature knob or your room thermostat. Make sure the heating mode is activated. Ensure that all radiator valves are open. Also, check that the boiler is receiving power by checking the fuses and switches, and verify the gas isolation cock is open. If the water pressure is too low (below 0.5 bar), re-pressurise the system.
  • M
    Mary SmithSep 23, 2025
    What does 'Parameter error' mean on my Baxi COMBI 228 Boiler?
    • K
      kelleymichaelSep 23, 2025
      If your Baxi Boiler displays 'Parameter error', it means there are incorrect parameters, so reset C1/C2.
  • A
    Amanda HughesSep 23, 2025
    What does communication error with the HMI PCB mean on my Baxi COMBI 228 Boiler?
    • L
      Lisa BrownSep 23, 2025
      If your Baxi Boiler shows a communication error with the HMI PCB, it means the HMI is not connected, so check wiring.
  • E
    Edgar SmithSep 10, 2025
    What causes a Baxi Boiler to display 'Return temperature sensor short-circuit'?
    • A
      Aaron GravesSep 12, 2025
      If your Baxi Boiler displays 'Return temperature sensor short-circuit', it could be due to: * Sensor not or badly connected: Check the wiring. * Bad connection: Check that the sensors are operating correctly. * Sensor fault: Check that the sensor has been correctly fitted and replace the sensor if necessary.
  • L
    loretta17Sep 12, 2025
    What causes a Baxi Boiler to display 'Flow temperature sensor open-circuited'?
    • K
      Kristen JohnsonSep 12, 2025
      If your Baxi Boiler displays 'Flow temperature sensor open-circuited', it could be due to: * Sensor not or badly connected: Check the wiring. * Bad connection: Check that the sensors are operating correctly. * Sensor fault: Check that the sensor has been correctly fitted and replace the sensor if necessary.
  • J
    Jason WilliamsSep 3, 2025
    What to do if my Baxi COMBI 228 has no circulation?
    • H
      Heather SmallSep 3, 2025
      If your Baxi Boiler has no circulation, it could be due to: * No circulation: Vent the air in the heating system. * Sensor not or badly connected: Check the water pressure and check the wiring. * Sensor fault: Check the circulation (direction, pump, valves), check the cleanliness of the heat exchanger, check that the sensors are operating correctly and replace the sensor if necessary.
  • W
    William CooperSep 1, 2025
    How to fix no circulation of water in my Baxi COMBI 228 Boiler?
    • C
      Crystal ArellanoSep 1, 2025
      If there is no circulation of water in your Baxi Boiler, it may be due to: * Non-existent or insufficient circulation: Check circulation. * Sensor error: Check water pressure, check sensors are operating correctly, check that the sensor has been correctly fitted, check the cleanliness of the heat exchanger and check pump.

Summary

Safety

General safety instructions

Safety guidelines for boiler use, including dangers and warnings.

Technical Specifications

Technical data

Detailed specifications including pressure, temperature, and electrical data.

Product Description

Control panel description

Details the keys and display elements of the boiler's control panel.

Boiler Operation

Start-up

Guides the user through the initial start-up and checking process of the boiler.

Use of the control panel

Explains how to operate the boiler using its control panel buttons and knobs.

Settings and Parameters

Setting the parameters

Guides on adjusting central heating and domestic hot water temperatures.

Maintenance

Maintenance instructions

Steps for checking the system, radiators, and repressurising.

Re-pressurising the system

Detailed steps on how to repressurise the heating system if pressure is low.

System Maintenance Procedures

Troubleshooting and Fault Finding

Error codes

Explains temporary and permanent error codes displayed by the boiler's control panel.

Fault finding

Provides a table of common problems, their causes, and solutions for the boiler.