Please keep these instructions in a safe place.
If you move house please hand them over to the next occupier.
United Kingdom
en
User Guide
High Efficiency Wall Hung Condensing Gas Boiler
Baxi Combi
224 – 228 – 424 – 428

Table of Contents

Other manuals for Baxi COMBI 228

Questions and Answers

  • J
    John WilliamsAug 31, 2025
    What should I do if my Baxi COMBI 228 shows a communication error between the gas valve and PCB?
    • O
      olivia22Sep 1, 2025
      If your Baxi Boiler displays a communication error between the gas valve and PCB, it could be due to a fault in the air/gas unit, in this case, replace the air gas unit. Alternatively, there might be a loose connection to the gas valve, so check the gas valve connection from the PCB.
  • S
    Sally SullivanAug 30, 2025
    What should I do if the CH Flow temperature is increasing too fast in my Baxi COMBI 228?
    • K
      Kristin McguireAug 30, 2025
      If the CH Flow temperature is increasing too fast in your Baxi Boiler, it could be due to: * Non-existent or insufficient circulation: Check circulation. * Sensor error: Check water pressure, check sensors are operating correctly, check that the sensor has been correctly fitted and check the cleanliness of the heat exchanger.
  • S
    schmidtalfredAug 29, 2025
    How to resolve a Baxi COMBI 228 Boiler's incorrect fan speed?
    • J
      James WilsonAug 29, 2025
      If your Baxi Boiler's fan speed is incorrect, it could be due to an external draught over the boiler, so check for adequate draw on the chimney connection. It may also be caused by a defective gas/air unit, so check the gas/air unit and replace it if necessary.
  • J
    Jon LeonAug 28, 2025
    What causes 5 x flame loss in 24 hours with burner on in Baxi COMBI 228?
    • K
      kimamberAug 28, 2025
      If your Baxi Boiler experiences 5 flame losses in 24 hours while the burner is on, possible causes include: * No ionization current: Purge the gas supply to remove air. * Sensor fault: Check that the gas valve is fully opened, check the supply pressure, check the operation and setting of the gas valve unit, check that the air inlet and flue gas discharge flues are not blocked and check that there is no recirculation of flue gases.
  • J
    Jason BoyleAug 27, 2025
    What causes no flame during operation in a Baxi COMBI 228?
    • B
      Benjamin SmithAug 27, 2025
      If there is no flame during operation in your Baxi Boiler, it could be due to several reasons: * No ionization current: Purge the gas supply to remove air. * Sensor fault: Check the gas valve is fully opened, check the supply pressure, check the operation and setting of the gas valve unit, check the air inlet and flue gas discharge flues are not blocked, check that there is no recirculation of flue gases.
  • M
    Michael MartinezAug 27, 2025
    Why are my radiators cold with my Baxi Boiler?
    • E
      Emily HoodAug 27, 2025
      If your radiators are cold when using your Baxi Boiler, first, check the temperature set point for the heating and increase it using the CH temperature knob or your room thermostat. Make sure the heating mode is activated. Ensure that all radiator valves are open. Also, check that the boiler is receiving power by checking the fuses and switches, and verify the gas isolation cock is open. If the water pressure is too low (below 0.5 bar), re-pressurise the system.
  • K
    Kenneth MillerAug 25, 2025
    How to fix no domestic hot water in my Baxi COMBI 228 Boiler?
    • C
      Christopher RossAug 26, 2025
      If your Baxi Boiler isn't providing domestic hot water, start by ensuring the boiler is receiving power by checking the fuses and switches. Also, verify that the gas isolation cock is fully open and, if applicable, that your prepayment meter has sufficient credit. It's also possible that the DHW function is switched off, so try activating the DHW mode. Check the water pressure; if it's below 0.5 bar, re-pressurise the system. Finally, make sure the flow is at least 2.5 litres per minute.
  • M
    Mark OrtegaAug 25, 2025
    What to do if my Baxi COMBI 228 has low system water pressure?
    • C
      Christopher PrestonAug 25, 2025
      If your Baxi Boiler shows low system water pressure, it could be due to a water leak. Check the boiler and the entire system for any signs of leakage. You may also need to repressurize the system.

Summary

Safety

General safety instructions

Safety guidelines for boiler use, including dangers and warnings.

Technical Specifications

Technical data

Detailed specifications including pressure, temperature, and electrical data.

Product Description

Control panel description

Details the keys and display elements of the boiler's control panel.

Boiler Operation

Start-up

Guides the user through the initial start-up and checking process of the boiler.

Use of the control panel

Explains how to operate the boiler using its control panel buttons and knobs.

Settings and Parameters

Setting the parameters

Guides on adjusting central heating and domestic hot water temperatures.

Maintenance

Maintenance instructions

Steps for checking the system, radiators, and repressurising.

Re-pressurising the system

Detailed steps on how to repressurise the heating system if pressure is low.

System Maintenance Procedures

Troubleshooting and Fault Finding

Error codes

Explains temporary and permanent error codes displayed by the boiler's control panel.

Fault finding

Provides a table of common problems, their causes, and solutions for the boiler.