Please keep these instructions in a safe place.
If you move house please hand them over to the next occupier.
United Kingdom
en
User Guide
High Efficiency Wall Hung Condensing Gas Boiler
Baxi Combi
224 – 228 – 424 – 428

Table of Contents

Other manuals for Baxi COMBI 428

Questions and Answers

  • A
    Aaron LeeSep 18, 2025
    What does 'Incorrect configuration settings C1/C2' mean on my Baxi Boiler?
    • K
      Kyle NguyenSep 19, 2025
      If your Baxi Boiler displays 'Incorrect configuration settings C1/C2', it means there is incorrect C1/C2, so reset C1/C2.
  • T
    Troy RomeroAug 25, 2025
    What to do if my Baxi COMBI 428 has low system water pressure?
    • J
      Jesse MontgomeryAug 25, 2025
      If your Baxi Boiler shows low system water pressure, it could be due to a water leak. Check the boiler and the entire system for any signs of leakage. You may also need to repressurize the system.
  • R
    roger04Aug 25, 2025
    How to fix no domestic hot water in my Baxi COMBI 428 Boiler?
    • K
      Karen JenkinsAug 26, 2025
      If your Baxi Boiler isn't providing domestic hot water, start by ensuring the boiler is receiving power by checking the fuses and switches. Also, verify that the gas isolation cock is fully open and, if applicable, that your prepayment meter has sufficient credit. It's also possible that the DHW function is switched off, so try activating the DHW mode. Check the water pressure; if it's below 0.5 bar, re-pressurise the system. Finally, make sure the flow is at least 2.5 litres per minute.
  • D
    David Levy DDSAug 27, 2025
    Why are my radiators cold with my Baxi COMBI 428 Boiler?
    • C
      Christina KimAug 27, 2025
      If your radiators are cold when using your Baxi Boiler, first, check the temperature set point for the heating and increase it using the CH temperature knob or your room thermostat. Make sure the heating mode is activated. Ensure that all radiator valves are open. Also, check that the boiler is receiving power by checking the fuses and switches, and verify the gas isolation cock is open. If the water pressure is too low (below 0.5 bar), re-pressurise the system.
  • J
    Jonathan MunozSep 23, 2025
    What does 'Parameter error' mean on my Baxi COMBI 428 Boiler?
    • J
      Joshua WardSep 23, 2025
      If your Baxi Boiler displays 'Parameter error', it means there are incorrect parameters, so reset C1/C2.
  • E
    Edward ThompsonSep 23, 2025
    What does communication error with the HMI PCB mean on my Baxi Boiler?
    • A
      amorrisSep 23, 2025
      If your Baxi Boiler shows a communication error with the HMI PCB, it means the HMI is not connected, so check wiring.
  • L
    lesterginaSep 10, 2025
    What causes a Baxi COMBI 428 Boiler to display 'Return temperature sensor short-circuit'?
    • I
      igonzalesSep 10, 2025
      If your Baxi Boiler displays 'Return temperature sensor short-circuit', it could be due to: * Sensor not or badly connected: Check the wiring. * Bad connection: Check that the sensors are operating correctly. * Sensor fault: Check that the sensor has been correctly fitted and replace the sensor if necessary.
  • A
    Ann FuentesSep 12, 2025
    What causes a Baxi COMBI 428 Boiler to display 'Flow temperature sensor open-circuited'?
    • A
      ashley53Sep 12, 2025
      If your Baxi Boiler displays 'Flow temperature sensor open-circuited', it could be due to: * Sensor not or badly connected: Check the wiring. * Bad connection: Check that the sensors are operating correctly. * Sensor fault: Check that the sensor has been correctly fitted and replace the sensor if necessary.
  • L
    Lindsey BraunSep 3, 2025
    What to do if my Baxi Boiler has no circulation?
    • J
      jordanrichardSep 3, 2025
      If your Baxi Boiler has no circulation, it could be due to: * No circulation: Vent the air in the heating system. * Sensor not or badly connected: Check the water pressure and check the wiring. * Sensor fault: Check the circulation (direction, pump, valves), check the cleanliness of the heat exchanger, check that the sensors are operating correctly and replace the sensor if necessary.
  • G
    George RodriguezSep 1, 2025
    How to fix no circulation of water in my Baxi COMBI 428 Boiler?
    • R
      Robert JamesSep 1, 2025
      If there is no circulation of water in your Baxi Boiler, it may be due to: * Non-existent or insufficient circulation: Check circulation. * Sensor error: Check water pressure, check sensors are operating correctly, check that the sensor has been correctly fitted, check the cleanliness of the heat exchanger and check pump.

Summary

Safety

General Safety Instructions

Essential safety guidelines for operating the Baxi Combi boiler, including warnings and precautions.

Recommendations for Safe Operation

Advice on system pressure, accessibility, and maintaining labels for optimal boiler performance and safety.

Technical Specifications

Dimensions, Connections, and Clearances

Diagrams and required clearances for installation, including connection points for the Baxi Combi boiler.

Product Description

Operation Guide

Boiler Start-up and Initial Checks

Step-by-step guide for initial boiler start-up and operational checks.

Basic Fault Identification during Start-up

Flowchart for diagnosing and resolving basic operational issues during boiler startup.

Settings and Adjustments

Adjusting Temperature Settings

Instructions for adjusting central heating and domestic hot water temperatures via control knobs.

Maintenance Procedures

System Checks and Cleaning

Steps for checking system pressure, radiators, and valves, and cleaning the boiler exterior.

Re-pressurising the Heating System

Procedure for topping up system water pressure using a filling loop, ensuring it's between 1-1.5 bar.

Troubleshooting Faults

Understanding Boiler Error Codes

Explanation of temporary and permanent error codes, their meanings, and reset procedures.

Common Problems and Solutions

Table listing common problems like no hot water or cold radiators with possible causes and solutions.

Decommissioning the Boiler

Warranty Information

Baxi COMBI 428 Specifications

General IconGeneral
Output Power28 kW
Fuel TypeNatural Gas
TypeCombination Boiler
Dimensions (H x W x D)700 x 400 x 285 mm
Water pressure1 bar