EasyManua.ls Logo

Baxtran MPI-6 - Calibration Procedure (CAL2)

Baxtran MPI-6
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ES FR ENG
User’s guide
MPI
16
3.
tA
- TARE FUNCTION
DISPLAY EXPLANATION
tA
0
One time taring
tA
1
Multiple taring is allowed
4.
Pr
- RS232 OUTPUT
DISPLAY EXPLANATION
Pr
LP-50
Parity: 8-N-1, LP-50 printer format (Baud rate must be 9600).
Pr
PC
Parity: 8-N-1, connecting to PC.
5.
br
- BAUD RATE
DISPLAY EXPLANATION
Br 2400
Set the baud rate to 2400
Br 4800
Set the baud rate to 4800
Br 9600
Set the baud rate to 9600
CALIBRATION PROCEDURE (CAL 2)
Notice: This section can only be operated by engineers.
Please have the jumper JP3 switch OFF before you start the calibration process.
In Calibration procedure, press to toggle among the options, and press to save the setting.
1. SEL MAXIMUM CAPACITY
DISPLAY MAXIMUM CAPACITY
LoAd 06
6 kg
LoAd 15
15 kg
LoAd 30
30 kg
2. DECIMAL POINTS
DISPLAY DESCRIPCIONES
Dp 0
Disable decimal points.
Dp 0.0
Set the price display to 1 decimal point.
Dp 0.00
Set the price display to 2 decimal points.
3. SPAN CALIBRATION
DISPLAY EXPLICACIÓN
SPAn
The Weight column and the Unit Price column display the Span Value.