Cell cleaning
The
Automatic
SALT
is equipped with an adjustable automat-
ic cell cleaning function. This function is based on the cy-
clic switching of the polarity of the chlorine generation
cell
and removes possible scale deposits on the cell sheets
with
each switching.
If you notice that your chlorine production cell tends to
calcify, you can shorten the polarity cycles. Please note
that a setting of 200 minutes or less will greatly reduce the
typical life of the chlorine production cell and will void the
warranty.
If you notice that your chlorine production cell remains
perfectly clean even after prolonged operation, you may
increase the polarity cycles. This may have a positive
effect on the life of the chlorine production cell.
Please note
The consistent use of Calcinex
®
and
pH-Minus Liquid
Anti Calc can extend the lifetime of the cell!
If, however, heavy limescale deposits have formed on the
cell sheets, you may manually clean the cell. To do this,
remove the cell from the cell holder (be sure to close the
taps of the bypass beforehand. Caution, water may leak
You can use the winterizing mode of your
Automatic
SALT
to winterize your pool. In colder conditions it is recommended
to take the Automatic
SALT
system out of operation.
The following procedures guide you to do so when either actively winterize your pool with a running ltration system or
passively winterize your pool system by also taking the ltration system out of operation.
For active winterising (ltration system of the pool
remains running)
Stop the lter pump.
Rinse pump hoses with clear water.
Empty all pump hoses.
Close and empty the bypass containing the Smart&Easy
connector and the production cell.
Remove the sensors from holders and store them in their
container, preferably lled with KCl storage solution, or
with pool water. Store the sensors in a dry and cool but
frost-free place.
Store your pH-Minus canister in a dry and cool but frost-
free place.
If there is no bypass, install ½" plugs in place of sensor
holders.
out) and treat it with BAYROL Cell Renov. Follow the
instructions on the product label.
Take the opportunity to also check the components in
the Smart&Easy Connector holder, as they may also be
calcied/dirty.
ATTENTION
Never try to remove the scale mechanically (e.g. with a brush
or metallic objects)! This will irreparably damage the cell.
A mechanically cleaned cell is excluded from the from the
warranty.
For passive winterising (ltration system of the pool is
shut off)
Stop the lter pump.
Rinse pump hoses with clear water.
Empty all pump hoses.
Close and empty the ltration system. Make sure to drain
the entire circulation system of the pool as much as
possible.
Close and empty the bypass containing the Smart&Easy
connector and the production cell.
Remove the sensors from holders and store them in their
container, preferably lled with KCl storage solution, or
with pool water. Store the sensors in a dry and cool but
frost-free place.
Store your pH-Minus canister in a dry and cool but frost-
free place.
37